
Electromagnetic Flowmeter M-910
28
Operation manual
Resolution
0.0000 for Q
100%
< 3.0000
0.000 for 3.000
≤
Q
100%
< 30.000
0.00 for 30.00
≤
Q
100%
< 300.00
0.0 for 300.0
≤
Q
100%
< 3000.0
0 for Q
100%
≥
3000.0
5.2.2.3
Volume units (2.3 VOLUME UNIT)
Function enables to set volume units after pressing the ENTER key. With the “Up” key any item from the list
“m3”, “l”, “US.G” and “user” can be set. To change the current valid unit to the selected unit press the ENTER
key. ESC key discards changes.
Available units:
m3
cubic metres
l
litres
US.G US gallons
user
user-defined unit, factory-set is „l“
(litres), user defined unit can be changed by computer only
Following values are pre-set:
Volume units standard factory setting:
Volume units
m3
User
l
5.2.2.4
Volume resolution (2.4 VOL. RESOL.)
Function enables to set volume resolution after pressing the ENTER key. With the “Up” key any item from the list
“0”, “0.0”, “0.00” , “0.000” and , “0.0000” can be set. To change the current valid resolution to the selected
resolution press the ENTER key. ESC key discards changes.
Available resolution:
0
without decimal digits
0.0
max. 1 decimal digit
0.00
max. 2 decimal digits
0.000 max. 3 decimal digits
0.0000 max. 4 decimal digits
Note: selected resolution is the maximuml resolution. It is reduced for high values. For example 4 decimal
digits resolution is valid up to -999.9999 or 9999.9999 displayed value. For higher values the resolution
is reduced (99999.999).
Following values are pre-set:
Volume resolution standard factory setting:
Resolution
0.000
5.2.2.5
Flowrate direction (2.5 FLOW DIREC.)
Function enables you to switch between “Positive” and “Negative” flow direction (change the sign in flowrate
value) after pressing the ENTER key. With the “Up” key any item from the list “Positive” and , “Negative” can be
set. To change the current valid direction to the selected direction press the ENTER key. ESC key discards
changes.
Note: flowmeters are working in both flow directions, however they are calibrated for positive direction only.
Following values are pre-set:
Flowrate direction standard factory setting:
Flow direc.
Positive