Operation manual
Valves
Suitable location of a shutoff valve is downstream of a sensor.
Removal during maintenance
If the application requires removal of the sensor for periodic maintenance, it is recommended to install a bypass
section as the following drawing.
Vibration
To avoid mechanical damage protect both electronic unit and sensor against mechanical vibrations. When strong
vibrations are possible, both the input and output pipe must be mechanically fixed or the remote version with a
separate electronic unit should be used.
Overheating
To avoid overheating, the electronic unit should be protected against direct sunlight especially in areas with a warm
climate with ambient temperatures over 30
o
C. If necessary a sunshade has to be mounted over the electronic unit
or a remote version with a separate electronic unit should be used.