Ariston PKL 751 A Operating Instructions Manual Download Page 13

GB

13

•  Do not leave the electric hotplate switched on without a pan placed on it.

•  The appliance should not be operated by people (including children) 

with reduced physical, sensory or mental capacities, by inexperienced 

individuals or by anyone who is not familiar with the product. These 

individuals should, at the very least, be supervised by someone who 

assumes responsibility for their safety or receive preliminary instructions 

relating to the operation of the appliance.

•  Do not let children play with the appliance.

   The appliance is not intended to be operated by means of an external 

timer or separate remote-control system.

Disposal

•  When disposing of packaging material: observe local legislation so that 

the packaging may be reused.

•  The  European  Directive  2012/19/EU  on  Waste  Electrical  and 

Electronic Equipment )WEEE(, requires that old household electrical 

appliances must not be disposed of in the normal unsorted municipal 

waste stream. Old appliances must be collected separately in order 

to optimise the recovery and recycling of the materials they contain 

and reduce the impact on human health and the environment.  

The crossed out “wheeled bin” symbol on the product reminds you of your 

obligation, that when you dispose of the appliance it must be separately 

collected. 

  Consumers should contact their local authority or retailer for information 

concerning the correct disposal of their old appliance.

Respecting and conserving the environment

•  Cook your food in closed pots or pans with well-fitting lids and use as little 

water as possible. Cooking with the lid off will greatly increase energy 

consumption.

•  Use purely flat pots and pans

.

•  If you are cooking something that takes a long time, it’s worth using a 

pressure cooker, which is twice as fast and saves a third of the energy.

Maintenance and care

Switching the appliance off

Disconnect your appliance from the electricity supply before carrying out 

any work on it.

Cleaning the hob surface

•   All the enamelled and glass parts should be cleaned with warm water and 

neutral solution.

•   Stainless steel surfaces may be stained by calcareous water or aggressive 

detergents if left in contact for too long. Any food spills (water, sauce, coffee, 

etc.) should be wiped away before they dry.

•   Clean with warm water and neutral detergent, and then dry with a soft 

cloth or chamois. Remove baked-on dirt with specific cleaners for stainless 

steel surfaces.

•   Clean stainless steel only with soft cloth or sponge.

•   Do not use abrasive or corrosive products, chlorine-based cleaners or pan 

scourers.

•   Do not use steam cleaning appliances.

•   Do not use flammable products.

•   Do not leave acid or alkaline substances, such as vinegar, mustard, salt, 

sugar or lemon juice on the hob.

Cleaning the hob parts

•   Clean the enamelled and glass parts only with soft cloth or sponge.

•   Grids, burner caps and burners can be removed to be cleaned.

•   Clean them by hand with warm water and non-abrasive detergent, 

removing any food residues and checking that none of the burner openings 

is clogged.

•   Rinse and dry.

•   Refit burners and burner caps correctly in the respective housings.

•   When replacing the grids, make sure that the panstand area is aligned 

with the burner.

•   Models equipped with electrical ignition plugs and safety device require 

thorough cleaning of the plug end in order to ensure correct operation. 

Check these items frequently, and if necessary, clean them with a damp 

cloth. Any baked-on food should be removed with a toothpick or needle.

!

 

To avoid damaging the electric ignition device, do not use it when the 

burners are not in their housing.

!

 It is not necessary to remove the pan supports in order to clean the hob 

surface. Thanks to the support system, simply lift and hold the pan supports 

or rotate them until they rest against a rear support.

Do not place the hot grids on top of the glass cover (if applicable), 

otherwise the rubber plugs on the glass may be damaged.

Gas tap maintenance

Over time, the taps may become jammed or difficult to turn. If this happens, 

the tap must be replaced.

!

 

This procedure must be performed by a qualified technician authorised 

by the manufacturer.

Troubleshooting

It may happen that the appliance does not function properly or at all. Before 

calling the service centre for assistance, check if anything can be done. First, 

check to see that there are no interruptions in the gas and electrical supplies, 

and, in particular, that the gas valves for the mains are open.

The burner does not light or the flame is not even around the burner.

Check whether:

•  The gas holes on the burner are clogged.

•  All the movable parts that make up the burner are mounted correctly.

•  There are draughts near the appliance.

The flame dies in models with a safety device.

Check to make sure that:

•  You pressed the knob all the way in.

•  You keep the knob pressed in long enough to activate the safety device.

•  The gas holes are not blocked in the area corresponding to the safety 

device.

Summary of Contents for PKL 751 A

Page 1: ...5 Mise en marche et utilisation 19 Pr cautions et conseils 19 Nettoyage et entretien 20 Anomalies et rem des 20 Sumario Manual de instrucciones 1 Advertencias 3 Asistencia 5 Descripci n del aparato 6...

Page 2: ...ur fonctionnement Ilfautfaireattention nepastoucher les l ments chauffants Ne pas faire approcher les enfants de moins de 8 ans moins qu ils ne soient soussurveillanceconstante Lepr sentappareilpeut t...

Page 3: ...ando a distancia ATENCI N el uso de protecciones inapropiadas de la placa de cocci n puede provocar accidentes Advert ncias ATEN O Este aparelho e as suas partes acess veis aquecem muito durante a uti...

Page 4: ...4 8 8...

Page 5: ...ses de habla hispana consulte a su vendedor Ampliaci n de garant a Llameal902 363 539yleinformaremossobreelfant sticoplandeampliaci n de garant a hasta 5 a os Consiga una cobertura total adicional de...

Page 6: ...nt l arriv e du gaz Descripci n del aparato Vista en conjunto 1 Parrillas de apoyo para RECIPIENTES DE COCCI N 2 QUEMADORES A GAS 3 Mandos de los QUEMADORES A GAS 4 Buj a de encendido de los QUEMADORE...

Page 7: ...7 1 2 3 4 5 5 4 1 2 3...

Page 8: ...t of a leak As a result LPG cylinders whether partially or completely full must not be installed or stored in rooms or storage areas that are below ground level cellars etc It is advisable to keep onl...

Page 9: ...current national regulations Before carrying out the connection make sure the cooker is compatible with the gas supply you wish to use If this is not the case follow the instructions indicated in the...

Page 10: ...increase this low flame setting using the adjusting screw 5 Oncetheadjustmenthasbeenmade replacethesealsontheby passes using sealing wax or a similar substance If the appliance is connected to liquid...

Page 11: ...60 122 H3 96 Z 79 6 103x2 248 157 95 343 At 15 C and 1013 25 mbar dry gas Propane P C S 50 37 MJ Kg Butane P C S 49 47 MJ Kg Natural P C S 37 78 MJ m Table 1 Liquid Gas Natural Gas Supply pressures Bu...

Page 12: ...ports are correctly fitted and that each pan is placed centrally over the burner Pan handles should be positioned in line with one of the support bars on the pan support grid Panhandleshouldbeposition...

Page 13: ...nersforstainless steel surfaces Clean stainless steel only with soft cloth or sponge Donotuseabrasiveorcorrosiveproducts chlorine basedcleanersorpan scourers Do not use steam cleaning appliances Do no...

Page 14: ...ocked There are no draughts near the appliance The minimum setting has been adjusted properly The cookware is unstable Check to make sure that The bottom of the cookware is perfectly flat The cookware...

Page 15: ...d incendie Une utilisation intensive et prolong e de l appareil peut n cessiter d une a ration suppl mentaire comme par exemple l ouverture d une fen tre A Exemples d ouverture de ventilation pour l...

Page 16: ...que latensiond alimentationestbiencompriseentrelesvaleursindiqu essur la plaquette signal tique la prise est bien compatible avec la fiche de l appareil Si ce n est pas le cas remplacezlapriseoulafich...

Page 17: ...n r glage de l air primaire R glage minimum 1 Placez le robinet sur la position de minima 2 D posez la manette et tournez la vis de r glage positionn e l int rieur ou sur le c t de la tige du robinet...

Page 18: ...1 236 2 60 1 65 1 00 3 60 122 H3 96 Y 79 6 103x2 248 157 95 343 Br leur Diam tre mm Puissance thermique kW p c s R duit Puissance thermique kW p c s Nominale By pass 1 100 mm Injecteur 1 100 mm D bit...

Page 19: ...guer le type de br leur reportez vous aux dessins figurant dans le paragraphe Caract ristiques des br leurs et des injecteurs Pour un maximum de stabilit assurez vous syst matiquement que les supports...

Page 20: ...d une peau de chamois Eliminez les r sidus carbonis s l aide d un produit de nettoyage sp cial pour surfaces en acier inoxydable Nettoyez l inox uniquement avec un chiffon doux ou une ponge N utilise...

Page 21: ...edudispositifdes curit nesont pas par hasard bouch s Le br leur s teint quand il est r gl sur la position de minimum Avez vous contr l si les orifices de sortie du gaz ne sont pas par hasard bouch s i...

Page 22: ...positan en las partes m s bajas Por lo tanto los ambientes que contienen botellas de GPL deben tener aberturas hacia el exterior para permitir la evacuaci n desde abajo de eventuales escapes de gas Ad...

Page 23: ...n a tierra y que sea conforme con la ley latomaseacapazdesoportarlacargam ximadepotenciadelam quina indicada en la placa de caracter sticas latensi ndealimentaci nel ctricaest comprendidadentrodelosv...

Page 24: ...su posici n todos los componentes siguiendo las operaciones en sentido contrario al de la secuencia descripta arriba Regulaci n de aire principal de los quemadores Los quemadores no necesitan de ningu...

Page 25: ...M ximo mbar 28 30 20 35 37 25 45 20 17 25 R pido Reduc RR Semi R pido S Auxiliar A Corona Triple TC 100 75 55 130 0 70 0 40 0 40 1 50 2 60 1 65 1 00 3 30 39 28 28 61 80 64 50 65x2 189 120 73 240 186 1...

Page 26: ...que deben utilizarse en placas de 75 cm 24 26 16 20 10 14 24 26 Quemador Di metro Recipientes cm Para identificar el tipo de quemador ver los dise os presentes en el p rrafo Caracter sticas de los que...

Page 27: ...ucho tiempo Limpie los restos de alimentos agua salsas caf etc antes de que se sequen Limpie la placa con agua tibia y detergente neutro y s quela a fondo con un pa o suave o una gamuza Limpie los res...

Page 28: ...esionado a fondo el mando por un tiempo suficiente como para activar el dispositivo de seguridad Est n obstruidos los orificios de salida del gas a la altura del dispositivo de seguridad El quemador e...

Page 29: ...asesdeliquefeitosdepetr leo maispesadosdoqueoar estagnam se embaixo Portanto as salas que contiverem cilindros de GLP devem possuir aberturas para fora de maneira que possibilitem o escoamento para ba...

Page 30: ...l ctrico e tomada da corrente deve ser f cil O cabo n o deve ser dobrado nem comprimido O cabo deve ser verificado periodicamente e substitu do somente por t cnicos autorizados veja aAssist ncia T cni...

Page 31: ...da torneira at obter uma pequena chama regular 3 Verifique se ao girar rapidamente o bot o da posi o de m ximo at a de m nimo os queimadores n o se apagam 4 Nos aparelhos equipados com dispositivo de...

Page 32: ...r M xima mbar 28 30 20 35 37 25 45 20 17 25 R pido Reduz RR Semi R pido S Auxiliar A Coroa Tripla TC 100 75 55 130 0 70 0 40 0 40 1 50 2 60 1 65 1 00 3 30 39 28 28 61 80 64 50 65x2 189 120 73 240 186...

Page 33: ...R pido S Auxiliar A Coroa Tripla TC 24 26 16 20 10 14 24 26 Queimador Di metro Recipientes cm Panelas para usar nos planos de 75 cm Paraidentificarotipodequeimador consultarosdesenhosapresentadosno p...

Page 34: ...rica Limpar a superf cie da placa Todas as partes de esmaltadas e de vidro devem ser limpas com gua quente e uma solu o neutra As superf cies em a o inoxid vel podem ficar manchadas por gua calc ria o...

Page 35: ...mador H correntes de ar nas proximidades do plano A chama n o permanece acesa nas vers es com seguran a Foi controlado se O bot o n o foi premido at o fundo N ofoimantidopremidoat ofundoobot oduranteu...

Page 36: ...36 AR 560 mm 45 mm 3 50 1 L 1 2 1 2 2000 1 7 2 1 3 4 1 7 2 1 3 1 2 3 4...

Page 37: ...AR 37 3 2 2 100 50 200 650 420 770 40 20 555 mm 55 m m 4 7 5 m m 30 20 40 20 45 x 560 600mm min 420mm min 650mm min...

Page 38: ...38 AR 5 2 3 5 5 1 RR 24 26 S 16 20 A 10 14 TC 24 26 3 l WEEE 2012 19 EU...

Page 39: ...H3 248 S 75 0 40 1 65 28 64 120 118 1 65 96 Y 157 A 55 0 40 1 00 28 50 73 71 1 00 79 6 95 TC 130 1 50 3 30 61 65x2 240 236 3 60 103x2 343 28 30 20 35 37 25 45 20 17 25 DCDR DRDA 2 1013 25 15 50 37 P...

Page 40: ...40 AR 195141389 02 04 2016 XEROX FABRIANO Indesit Company S p A Viale Aristide Merloni 47 60044 Fabriano AN www hotpoint ariston com...

Reviews: