33
4. commissioning
parameter
EGIS HE 24
EGIS HE 30
G20
G20
Lower Wobbe index (15°C, 1013 mbar) ( MJ/m3)
45.67
45.67
Soft ignition
220
60
60
Minimum fan speed (%)
233
13
16
Maximum central heating fan speed (%)
234
93
94
Maximum D.H.W fan speed (%)
232
93
94
Maximum heating power adjstment
231
70
60
Gas valve restrictor (ø)
NO
NO
Gas fl ow max/min
(15°C, 1013 mbar)
(nat - m3/h) (GPL - kg/h)
max
2.49
3.07
min
0.48
0.63
4.5.4 Table summarising changes
4.5.5 Changing the gas supply
It is not possible to convert this boiler from Natural
Gas to LPG.