8. maintenance guide
8.3.16 Manual Air vent
Tools
TIME
5 min
Drain boiler (see 3.3)
Unscrew and lift the manual air vent from the exchanger
1
8.3.15 Overheat thermostat
Tools
TIME
5 min
Remove the electrical connections
Unscrew the screw nad remove the overheat thermostat
1
Remove the clip and the temperature sensor
3
IMPORTANT !
Do not use conducting paste for the
contact sensors because it will alter the resistance
value.
TEMPERATURE
RESISTANCE (kOhm)
0
27
10
17
20
12
25
10
30
8
40
5
50
4