EN - 39
MENU
SUB
-MENU
PAR
AME
TER
DESCRIPTION
RANGE
0
NETWORK
0
2
BUS network
0
2
0
Current BUS network
Boiler
System interface
Energy Manager
Heat pump
Room sensor
Multizone control
0
3
System interface
0
3
0
Zone number
No zone selected
Zone selected
0
3
1
Room temperature correction
- 3; +3
0
3
2
Interface SW version
4
ZONE 1 PARAMETERS
4
0
Temperature settings
4
0
0
Daytime temperature
10 - 30 °C
4
0
1
Night-time temperature
10 - 30 °C
4
0
2
Set Z1 temperature
par. 4.2.5 - 4.2.6
4
0
3
Zone anti-frost temperature
2 - 15 °C
4
1
Automatic summer/winter function
4
1
0
Activating auto summer/winter
OFF - ON
4
1
1
Auto summer/winter temperature limit
10 - 30 °C
4
1
2
Summer/winter switching delay
[0-600]
4
2
Zone 1 settings
4
2
0
Temperature range
Low temperature
High temperature
4
2
1
Temperature adjustment type selection
Fixed delivery temperature
Devices ON/OFF
Room sensor only
Outdoor sensor only
Room Outdoor Sensor
4
2
2
Temperature adjustment curve
0.2 - 1 (LT); 1 - 3.5 (HT)
Menu table