Ignition Switch (988316, 319)

Operate the ignition switch with the removable 
key. The switch uses two positions: Off (1) and 
On (2). To start the engine, turn the key to On 
(2) and pull the recoil handle. To stop the 
engine, turn the key to Off (1).

Throttle Lever

The throttle lever changes the speed of the 
engine. Move the throttle lever to Fast (1) to 
increase engine speed. Move the lever to Slow 
(2) to decrease engine speed.

Choke Control 

Use the choke control to start a cold engine. Pull 
the control out to choke the engine. Push the 
control in when the engine gets warm.

PTO Clutch 

Pull the PTO (power take off) switch past On (1) to Reset (2) 
to engage the mower blades. Push the PTO switch Off (3) to 
disengage the mower blades. 

NOTE: Pull PTO switch to Reset (2) to engage mower 
blades after operator presence control has been released.

Parking Brake

The parking brake holds the tractor in position 
when not in use. 

To engage parking brake, pull the brake handle 
back (1). 

To release parking brake, push the brake handle 
forward (2).

Recoil Starter Handle

Pull the recoil starter handle to start the engine.

Hour Meter

Recoil Start: The hour meter measures the 
number of hours the engine has been run.

Oil Pressure Light (988320)

The red light near this symbol comes on when 
the engine is running and engine oil pressure is 
low. Check oil level and add if necessary. See 
Engine Manual.

Cold Start Disengage

Use the cold start disengage for easier starting on cold days.

1. Pull out cold start chain 1 to 4 links and lock chain in 

frame notch (Figure 5).

2. Start engine and allow engine to warm to operating 

temperature.

3. Slowly release chain from notch.

FILL FUEL TANK

OF1212

OG1180

1

2

OG1190

OE0261

1

2

3

1

2

WARNING: AVOID INJURY. Unit will move if 
steering controls are engaged when cold start 
feature is released.

WARNING: Fuel is highly flammable and its 
vapors are explosive. Handle with care. Use an 
approved fuel container.

NO smoking, NO sparks, NO flames. ALWAYS 
allow engine to cool before servicing.

NEVER fill fuel tank when engine is running or 
hot from operation.

NEVER fill or drain fuel tank indoors.

Replace fuel cap securely and clean up spilled 
fuel.

OG0620

OG0600

Figure 5

OG1320

Cold Start 
Disengage

Notch

Summary of Contents for 988316

Page 1: ...ale del proprietario opera tore Manual del operador propietario Manual do Propriet rio Operador Instrukcja Obs ugi Operatora 988316 HR1536FXPCE 988319 HR1544FXPCE Rear Discharge 988320 HE1748FLPCE Hyd...

Page 2: ...el Mod le Modell Model Model Modello Modelo Modell Modell Malli Model Modelo Cutting Width Largeur de coupe Schnittbreite Maaibreedte Klippebredde Larghezza di taglio Ancho de corte Klippebredde Klipp...

Page 3: ...umentacj Techniczn Gestor de Qualidade e Conformidade Zelador de Arquivos T cnicos Ariens Company Brillion WI 54110 0157 USA Signature Signature Unterschrift Handtekening Underskrift Firma Firma Signa...

Page 4: ...et UNAUTHORIZED REPLACEMENT PARTS Use only Ariens replacement parts The replacement of any part on this vehicle with anything other than an Ariens authorized replacement part may adversely affect the...

Page 5: ...al and any needed safety training before operation SAFETY DECALS AND LOCATIONS ALWAYS replace missing or damaged Safety Decals Refer to figures below for Safety Decal locations SAFETY WARNING This cut...

Page 6: ...tc can reduce vision and cause an accident Operate unit only when there is good visibility and light Read the operator s manual Keep children and others away from unit while operating Never direct dis...

Page 7: ...radius and clearance ALWAYS keep protective structures guards and panels in good repair in place and securely fastened NEVER modify or remove safety devices ALWAYS keep discharge cover or complete gra...

Page 8: ...es or clothing can cause severe chemical burns No flames No sparks No smoking near battery ALWAYS wear safety glasses and protective gear near battery Use insulated tools DO NOT TIP battery beyond a 4...

Page 9: ...l tank See engine manual for type and grade 8 Check for loose hardware 9 Be sure that safety interlock system operates correctly See Check Safety Interlock System on page 11 10 Be sure that unit track...

Page 10: ...ydraulic Fluid Tank 9 Recoil Starter Handle 10 Cold Start Disengage 11 Ignition Switch 12 Bypass Valve Levers 13 Control Levers 14 Control Stop Lock Lever 15 Pivot Bar 16 Muffler Guard 17 Mower Lock P...

Page 11: ...PTO is engaged releasing the operator presence control levers stops the mower blades Control Levers The control levers are used to steer operate in forward and reverse and stop the unit Push forward t...

Page 12: ...handle forward 2 Recoil Starter Handle Pull the recoil starter handle to start the engine Hour Meter Recoil Start The hour meter measures the number of hours the engine has been run Oil Pressure Ligh...

Page 13: ...refer to Engine Manual 10 After engine starts adjust choke as needed Allow engine to warm and run smoothly before operating unit Electric Start 988320 To start the engine 1 Engage parking brake 2 Brin...

Page 14: ...1 Shut off the unit See Shut Off on page 13 and To stop mowing 2 Lift deck by handle until mower lock pins can be pulled out of holes 3 Turn latches slightly so they can t snap back into place 4 Set d...

Page 15: ...1 Rotate the bypass valve levers located on the back side of the pumps approximately 1 2 turn counterclockwise 2 Release parking brake 3 Push unit to desired location 4 Rotate the bypass valve levers...

Page 16: ...proper inflation excessive wear or damage before each use The correct air pressure is 8 to 16 psi 55 to 110 kPa Check Hydraulic Fluid Level Check hydraulic oil level mark on cap dipstick Add 15W 50 s...

Page 17: ...onto seal of new filter 8 Install new filter and hand tighten securely 9 Fill system with about 44 oz 1 3L fresh clean hydraulic oil See Specifications for proper type 10 Run in hydraulic system to b...

Page 18: ...acking on page 18 2 Slowly pull both control levers all the way back 3 Note which direction if any the unit pulls 4 Stop unit and engine 5 Adjust tracking if needed If unit turns to the right 1 Reduce...

Page 19: ...eed range 4 Connect clevis to return to neutral bracket on the hydraulic pump with clevis pin and hairpin 5 Repeat steps 1 4 for the other pump 6 Check and adjust tracking as needed REPLACING HYDRO PU...

Page 20: ...st if needed BATTERY 988320 Unit comes equipped with a maintenance free battery that requires no regular maintenance except cleaning the terminals Check Battery Terminals Inspect battery and terminals...

Page 21: ...ing the engine to run Jump Starting Ariens does not recommend jump starting your unit Jump starting can damage engine and electrical system components See your engine manual for more detailed informat...

Page 22: ...the ignition wire from the spark plugs 2 Remove the bolts lock washer flat washers and blades from the spindle shafts Replace Mower Blades 1 Put the blades flat washers lock washers and the bolts bac...

Page 23: ...r storage Battery Remove battery and store in a cool dry place CAUTION DO NOT sharpen mower blades while on unit An unbalanced mower blade will cause excessive vibration and eventual damage to unit Ch...

Page 24: ...wer 1 Binding in the steering or parking brake linkage 2 Steering levers out of adjustment 1 Check linkage for debris or damage Repair if necessary See Parking Brake Adjustment on page 18 or your Deal...