2.2.5 Power supply unit installation
Before installation, assure that the AC plug is not plugged into the AC outlet. The PSU is located at the
left-most area of the KSU as a basic unit and provides three kinds of power sources to MBU through the
7PIN connector, CN19.
Aria-24/A ipe
The AC input voltage and the fuse rating
The Range of Input Voltage
Connect to
Fuse Ratings
207V AC ~ 253V AC
CN19 on the MBU
1A @250V
PSU capacity is as followings
PSU Type
+5V DC
-5V DC
+36V DC
PSU (SMPS)
2.5A
100mA
1.2A
Aria-24/D ipe
The AC input voltage and the fuse rating
The Range of Input Voltage
Connect to
Fuse Ratings
207V AC ~ 253V AC
CN19 on the MBUB
1.25A @250V
PSU capacity is as followings
PSU Type
+5V DC
-5V DC
+30V DC
PSU (SMPS)
3.0A
100mA
1.9A