![Argus Copper Box v4 Manual Download Page 35](http://html1.mh-extra.com/html/argus/copper-box-v4/copper-box-v4_manual_2969459035.webp)
7 Voltage measurement (U= and U~)
ARGUS Copper Box
35
7 Voltage measurement (U= and U~)
Voltage measurement enables detection of e.g. connected accesses (such as ISDN-BRI U
or POTS) and supply voltages (as for SHDSL using ZWR) and external voltages, such as a
connection to another line.
In AC voltage measurement, the frequency (10 - 200 Hz) is additionally displayed. This also
enables identification of call switching and coupled voltages as well as carrier or
power frequencies.
Note that unexpected or hazardous mixed voltages or hazardous voltage
peaks can occur. All voltages >200V are outside the permissible limits.
See the chapter Technical data page 14 for information on measuring ranges, resolutions
and accuracies of voltage measurement.
Setting Voltage measurement:
ARGUS in the status display.
The voltage measurement is not yet
started.
<Start>
Starts voltage measurement
between sockets Tip and Ring.
Hotkeys/settings
<Menu>
Opens the Copper Box menu,
see page 20.
Input resistance, s. page 36
Press one after
another
and
Remote kit command,
s. page 83
Remote kit, s. page 81
Information bell, s. page 36
Press one after
another
and
Copper Box info, s. page 21
Press one after
another
and