18 Remote kit control (Rem.)
ARGUS Copper Box
83
The command has been sent to the
remote unit.
Commands:
Description:
Short circuit a/T-b/R
The instrument kit short-circuits the Tip and Ring wires, e.g. for
loop resistance measurement.
Exchange connect
The instrument kit switches the line through. On a DSL access for
example directly to the DSLAM.
Short circuit a/T-
b/R-/GND
The instrument kit shorts Tip, Ring and Ground, e.g. for resistance
symmetry measurement.
Open circuit
The instrument kit opens a line, e.g. for a capacitance
measurement.
Tone mode
The tone generator in the instrument kit is activated. The tone can
be followed.
Port 1 loop 3 sec.
(90x)
The instrument kit type 900/905 creates a loop on port 1 for
3 sec.
Port 1+3 connect
(90x)
The instrument kit type 900/905 connects port 1 with port 3.
P1+2 & 3+4 connect
(90x)
The instrument kit type 900/905 connects port 1 with port 2 and
port 3 with port 4.
Port 1+4 connect
(90x)
The instrument kit type 900/905 connects port 1 with port 4.
Port 1+4 loop (90x)
The instrument kit type 900/905 creates a loop (short-circuit)
between port 1 and port 4.
Port 4 loop 3 sec.
The instrument kit type 900/905 creates a loop on port 4 for 3 sec.
Port 2+4 connect
(90x)
The instrument kit type 900/905 connects port 2 with port 4.
Port 3+4 connect
(90x)
The instrument kit type 900/905 connects port 3 with port 4
<Start>
Selects and sends a new
command.