![Argus Copper Box v4 Manual Download Page 14](http://html1.mh-extra.com/html/argus/copper-box-v4/copper-box-v4_manual_2969459014.webp)
3 General technical data
14
ARGUS Copper Box
Measuring accuracies:
Voltage:
DC voltage measurement (U=):
Measuring range:
Resolution:
Accuracy:
0.01 V - 9.99 V
0.01 V
±(0.5 % + 2 digits)
10.0 V - 200.0 V
0.1 V
±(0.5 % + 2 digits)
AC voltage measurement (sine, 50 Hz) (U~):
Measuring range:
Resolution:
Accuracy:
0.01 V - 9.99 V
0.01 V
±(2 % + 2 digits)
10.0 V - 200.0 V
0.1 V
±(1.5 % + 2 digits)
Frequency: 10 Hz to 200 Hz; 0.2 Hz; ±(1.5 % + 2 digits); sine
When measuring voltages, the input resistance depends on the measuring range:
- Measuring range 1: 0 V - 25 V; Input resistance: 1.694 M
Ω
- Measuring range 2: 25 V - 200 V; Input resistance: 1.05 M
Ω
As soon as the total of all voltages exceeds 25 V, the measurement is switched over.
Capacitive symmetry measurement (C
Sym
):
Measuring range:
Resolution:
Accuracy of capacity diffe-
rence:
10 nF - 4 µF
0.01 nF
0.1% of the capacity to
ground
Capacitive measurement, measuring frequency 8 Hz (C):
Measuring range:
Resolution:
Accuracy:*
0.01 nF - 9.99 nF
0.01 nF
±(4 % + 4 digits)
10.00 nF - 99.99 nF
0.01 nF
±(4 % + 4 digits)
100.0 nF - 999.9 nF
0.1 nF
±(3 % + 1 digit)
1000 nF - 8000 nF
1 nF
±(3 % + 1 digit)
* All specifications relate to a comparison measurement using film capacitors.