9 Capacitance measurement (C)
ARGUS Copper Box
47
Starting capacitance measurement
ARGUS in the status display.
In this example, a capacitance of approx.
48 nF is measured between each of the
sockets Tip/Ring and Ground.
For a specific capacitance of approx.
50 nF/km, this value indicates that the line
is approx. 1 km long and open.
No measurement is possible on a closed
line. ARGUS indicates this with the
message "Loop?".
Settings
Description
Wire types:
See page 30 for an explanation of wire types.
Susceptibility:
See page 43 for an explanation of susceptibility.
When you select the susceptibility
"Insecure (fast)", the red warning
"ATTENTION: susceptible"
appears on the display.
<Start>
Starts capacitance
measurement