Press PROG key

 

 

 

Press registered  remote 

key fob or enter your PIN

  

SENSOR  appears on LCD

 

ready to register key fob or detectors

 

 

4.5 Selectable key fob require assistance with/without sounder

 

 

How to set the function: Press 'Sensor ’ key and - - - appears on the LCD. Press the disarm 

key on the registered Key Fob or  entering the  preprogrammed PIN code,  LCD will  display

 

'DEL Sensor' Use Key pad to select Zone(s) 0, then select key fob number 1 to 9.Program the 

character  of the Key  Fob with 0 or 1 to suit.  Press Key Fob or ESC to save and exit.  refer to

 

figure 25.

 

 

 

LOG

 

 
 

H  

M         D

 

ALM

 

 

 
 
 
 

Figure7 : LCD display when alarmed

 

 

4.6 Omitting a Zone

 

 

It may be a requirement to temporarily omit a selected Zone or a number of Zones when 

the system is armed. When a zone is selected to be omitted it will only be omitted for current 

operation.  When  next time  your  System is armed, the  omitted  ZONE or  ZONES  will  be 

re-enstated into the system.

 

 

Note:  The function is suitable for the armed zone or zones. But 24  hour zone can  never 

be omitted.

 

 

How to Omit a zone or zones: Press Arm button on the panel, then using the numeric 

keypad on the panel press the number of the zone want to be omitted, then press the Disarm 

key, enter the PIN code to complete the operation.

 

4.7 Sounder or Silent alarm setting:

 

The figure  shows that  Zone 3 detector No2  has  generated the  Alarm signal at 6:10  on

 

18

th

, Oct.

 

 

 

3  INSTALLATION INFORMATION

 

 

3.1 The Basic Flow Chart for Registering Devices, Set Zone Type, 

Set System Configuration and Program C.S. phone numbers and 
Site Code in Disarmed mode.

 

 

 

1 To register Key fobs

 

2 To register Detectors

 

3 To set Zone type

 

4 To set System configuration

 

5 To set C.S phone NO and account

 

 

 

Activate the key fob to be register CODE  appears on LCD, comfirming  the code has been received .

 

How to set the function: Press the # key for 2 seconds when the panel is in disarmed mode, 

the symbol of speaker displays or disappears; When it displays,  the  panel would alarm with 

sounder ON, while when it disappears, the panel will alarm silently.

 

Note: Whether the key fob alarms with/without sounder subjects to its own configuration. 

When the panel is set with silent alarm, the key fob will still be sounder alarm if it is set with 

sounder alarm.

 

4.9 Access the Control Panel from a remote telephone (mobile or 
land line)

 

The Remote Control  enables the use of the land  line phone or mobile  phone to remotely 

control panel. Call the phone number of the line connected to the alarm panel, the panel  will 

answer the call after 1 to 8 rings (programmable). When the panel  answers the call enter  the 

pre-programmed 6 digit PIN code on the phone keypad to gain access to the Panel.

 

If the correct 6 digit PIN code is entered a long tone will be emitted from the panel. If the

 

PIN code is incorrect, three short tones will be emitted from the panel.You must try again and 

enter the correct PIN code.

 

To register Key fobs

 

 

 

OR

 

 

To register Sensors

 

 

 

OR

 

 

To set zone type

 

 

 

OR

 

To set system config

 

 

 
 

OR

 

 

To set C.S phone number

 

Press 0 to select key fob zone. Unit will auto register key fob with next reg. No , eg. If already 2 key 
fobs registered,  the new key fob will be allocated No 3.Press PROG to save the code. SENSOR 
appears again to register more devices or press registered  key fob  to exit

 

 

 

Activate the detector to be registered CODE appears on LCD, confirming the code has been received 
Press 1--8 to select the zone you wish the detector to be allocated to. Unit will auto register the de- 
tector with next reg. No, eg, if already 3 detectors registered, the new detector will be allocated No 4. 
Press PROG to save the code. SENSOR appears again to register more devices or press registered key 
fob  to exit

 

 

 

Press * key ,LCD will display ZONE TYPE, press 1---8 to select zone, select 1 or 0 for all 7 fields 
per zone. Press  PROG to save. Press * key, LCD will display ZONE TYPE to reset the other ZONE 
TYPE or press registered key fob  to exit

 

 

 

Press # key, LCD will display SYS CONFIG, press 00 to 17  to select the configuration of the system. 
Press PROG to save. Press # key, LCD will display SYS CONFIG to re_configure the system or press 
registered  key fob  to exit

 

 

 

Press * key, then press # key, the LCD will display PHONE , press 1 and display current C.S. Pry 1 
phone No, enter new Pry 1 phone No, press PROG  to save the phone, press * key then # key, the LCD 
will display PHONE, press 2 and display current C.S. Pry 2 phone No, enter new Pry 2 phone No, 
press PROG to  save, using this way, can set C.S. Account in Pry 7. or other private phone No, press 
the registered key fob  to exit

 

 

21 

6

 

Summary of Contents for ZDAS-300

Page 1: ...Luxury Voiced LCD Alarm System USER S MANUAL Model ZDAS 300 Thank you for choosing our panel Please read the manual carefully before fixing it ...

Page 2: ......

Page 3: ...VIEW 1 1 1 Introduction 1 1 2 Basic Principle of Operation 1 1 3 Component Parts 2 1 4 Optional Extra Detectors available 2 2 DESCRIPTION 3 2 1 The Keypad 3 2 2 The LCD Character details and description 4 3 INSTALLATION INFORMATION 9 3 1 The Basic Flow Chart 6 3 2 Registering Key Fobs 7 3 3Registering Sensors 7 3 4 Installing Wired Detector 8 3 5 Checking Registration 8 3 6 Deleting Registered Key...

Page 4: ...s PROG to save using this way can set C S Account in Pry 7 or other private phone No press the registered key fob ESC key to exit To set C S phone number 1 To register Key fobs 2 To register Detectors 3 To set Zone type 4 To set System configuration 5 To set C S phone NO and site code 1 OVERVIEW 1 1 Introduction 1 Blue backup LCD display everything you want to konw about the panel 2 Full complianc...

Page 5: ...the Alarm Signals from the various Detectors It also contains the central Station communicator and By directional Audio Verification mechanism Everything you need to know about the security system is displayed on the panel keypad LCD The zones 24 Hours Armed Part armed Disarmed and the important Messages regarding system status are displayed on the LCD screen See section 2 1 and 2 2 Wireless Remot...

Page 6: ...tect the particular frequency and then transmitting an alarm signal to the control panel 1 2 3 4 5 6 7 1 1 watchdog zone 0 not a watchdog zone 2 1 exit delay 0 no exit delay 3 1 entry delay 0 no entry delay 4 1 24 hours zone 0 not 24 hours zone 5 1 sounder when alarming 0 silent when alarming 6 1 armed zone 0 part armed zone 7 1 sensor in the zone 0 no sensor in the zone Zone 1 selected 2 DESCRIPT...

Page 7: ...ng system status appear on the LCD screen LOG M D H M D 2 2 The LCD Character details and description 2 2 1 The panel LCD screen whole information shows as follows Figure 23 Detector No 2 in zone 3 is low voltage LOG DIS PART ARMED WatchDog M D H M D B When the panel is in the Armed PART Armed mode if the detector such as PIR detects itself being low voltage the panel will sound a beep every secon...

Page 8: ... is transferred to the C S the operator then has access to the customer details address name phone numbers 2 2 2 When the panel is set in the away armed mode the LCD screen will show the following ARMED key holders etc He also has audio access to the premises He can Listen in or Speak to the occupants this will allow the C S operator to request a pre arranged password to confirm the identity of th...

Page 9: ... fob will still be sounder alarm if it is set with sounder alarm 4 9 Access the Control Panel from a remote telephone mobile or land line The Remote Control enables the use of the land line phone or mobile phone to remotely control panel Call the phone number of the line connected to the alarm panel the panel will answer the call after 1 to 8 rings programmable When the panel answers the call ente...

Page 10: ...ows particular detectors in each Zone to be local alarm only or local alarm and transmit alarm information to the C S each detector can be configured differently e g local Alarm only or local Alarm and C S function door bell function or in the case of Key Fob Request Assistance with without sounder How to set the function press Sensor key and appears on the LCD Press registered Key Fob or entering...

Page 11: ...n the keypad a series of appear on the LCD Enter the PIN code or press the Disarm key on a registered key fob and the word Sensor will appear on the LCD Trigger the detector you wish to register the panel will receive the detectors code and the word CODE will appear on the LCD Pressing a numeric key 1 to 8 on the keypad will select the zone you wish to allocate the detector e g Pressing No 3 on th...

Page 12: ...e No 2 detector in Zone 3 If no further actions take place the panel will automatically return to normal state after approximately 30 seconds Otherwise at the end press Dis Arm key on a registered Key Fob to return the panel to normal state 3 8 The Zone Setting and Allocation The alarm system has 8 zones which can be configured depending on your requirements The Factory Default Zone configuration ...

Page 13: ...d PIN code and the word Sensor will appear on the LCD Pressing the key on the Keypad the LCD will show the words Zone type pressing No1 to 8 numeric key to select corresponding zone then pressing the 0 or 1 numeric Keypad to configure all the fields in this zone At the end press the PROG key to complete and save operation By way of example below is configured as follows Zone 7 selected is a Watchd...

Page 14: ...04 20 seconds 02 Entry delay time delay alarm The time is double digit XX The actual time is the product of XX times 5 The initialization value is 06 30 seconds 03 Sounder run time The time is double digit XX The actual time is the product XX times 20 The initialization value is 06 120 seconds 04 Watchdog time The unit time is hours The factory default value is 12hours 05 Watchdog start and stop t...

Page 15: ...is required within 2 5 seconds after transmitting data to the C S the Panel Will receive the SPEAK request from C S If it is not required the panel hangs up automatically ALM phone line cut_off alarm Figure15 The LCD display when the phone line is cut 13 Engineer Option Listen to dial out DTMF 0 NO 1 YES This option will Automatically extinguish when the panel is closed or on the hour Default 0 14...

Page 16: ...e account code using the numeric keypad on the panel this is normally a 4 Digit Code called site code Press Prog key to store the programmed number If no further actions take place the panel will automatically return to normal state after approximately 30 seconds Otherwise at the end press the Dis Arm key on a registered Key Fob to return the panel to normal state 3 12 Deleting Zones How To Delete...

Reviews: