background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If after 15 seconds the user does not press the * key  to  confirm the alarm, the  panel  will 

auto dial next phone number.

 

After the entry of the listening in status, the next operating steps are same as the remote 

control In section  4.9 previous.

 

 

4.11 Detector Battery Low Voltage Display On the Panel And Introduction

 

 

When detector has been in the low voltage  state, it  will not run correctly.  The Panel can 

receive the detector low voltage signal and display on  the LCD and sound a beep  to indicate 
user to replace detector's battery in time.

 

 
 
 
 
 
 
 

+12

V    JD   

Auto    

L7       L6 

output

 

 

1 2 V   i n p u t

 

 
 
 
 
 
 

 

L5       L4       L3

 

 
 
 
 
 
 

 

L2       L1   LAMP GND

 

Note:

 

GND:  the  negative  electrode  of the 

power  supply , siren , wired 
detector and alarm output

 

 

L1.L2.L3.L4.L5.L6.L7 (wired detector):

 

 

 

lamp out:  connect  the relay  for  turn 

on the lamp,  this  signal   is 
high-low contral

 

+12v:  continued  output  for the wire

 

Power

 

 

Low voltage display and introductions:

 

 

A: When the panel is in the DISARMED mode, if the detector such as PIR detects itself

 

Phone

 

Phone line

 

ON 

OFF

 

sensor or other accessaries

 

 

JD:  output 12V for  the  wired  siren or 

other accessaries when alarm

 

being low voltage, the panel will sound a  beep every seconds and display the signal

 

On the LCD continually.

 

Figure 3: The back view of the panel

 

Everything you   need to know about your  Security  System is  displayed on  the  Panel 

keypad. The zones armed or disarmed and the important messages regarding  system  status 
appear on the LCD screen.

 

 

 

LOG

 

M  

H  

M  

D

 

2. 2 The LCD Character details and description

 

2.2.1 The panel LCD screen whole information shows as follows:

 

 
 

 

 

Figure 23: Detector No 2 in zone 3 is low voltage

 

 

 

LOG

 

DIS PART 
ARMED 
WatchDog

 

 

 

M  

H  

M  

D

 

B: When the panel is in the Armed/PART Armed mode, if the detector such as PIR detects

 

itself being low voltage, the panel will sound a beep every seconds and display the signal 

armed zone and detectors No on the LCD alternately.

 

 

C: Even  if the panel LCD displays the  detector low  Voltage, the  operation  also  can  be 

done normally on the panel and stop provisionally low voltage display.

 

SETRMOT TYPECONFIG ALM 

PIN TESTTIMED GSM PHONE

 

 

 
 
 
 
 

ON=Sounder as alarm

 

OFF=Silent as alarm

 

How to cancel the low voltage display:

 

 

A:  Press 'Delete' key and - - - appears on the LCD. Press registered Key Fob or enter your 

PIN, LCD will display 'DEL Sensor' u se keypad to select zone(s) 1 to 8. Use Keypad to select 

Detector(s) 1 to 9. Program the 4th field with 0. Press Key Fob Exit. (Refer to figure 25)

 

B: Press the key Fob

 

 

 
 

N.B.: When the battery has been replaced, the  user  must  program  the 4the  field   with 0

 

ARMED

 

DIS  ARMED 

PARTARMED 

Watchdog

 

 

LOG

 





D

 

Panel armed 
Panel disarmed 
Panel part armed 
Avaible

 

 

Event  log

 

Month 
Day 
Hour 
Minute

 

Weekday

 

SET 
RMOT 
TYPE 
CONFIG 
ALM

 

 

PIN 
TEST 
TIMED 
GSM 
PHONE

 

Set program

 

Remot Zone 
type System 
config Alarm

 

Wireless  sensor battery low voltage

 

Pin code

 

Walk test

 

Timed auto arm or disarm

 

GSM signal avaible

 

C.s. Phone or user owner phone

 

 

manually. And then the panel will display normally.

 

 

Figure 4: All the info. the LCD displays

 

 

23 

4

 

Summary of Contents for ZDAS-300

Page 1: ...Luxury Voiced LCD Alarm System USER S MANUAL Model ZDAS 300 Thank you for choosing our panel Please read the manual carefully before fixing it ...

Page 2: ......

Page 3: ...VIEW 1 1 1 Introduction 1 1 2 Basic Principle of Operation 1 1 3 Component Parts 2 1 4 Optional Extra Detectors available 2 2 DESCRIPTION 3 2 1 The Keypad 3 2 2 The LCD Character details and description 4 3 INSTALLATION INFORMATION 9 3 1 The Basic Flow Chart 6 3 2 Registering Key Fobs 7 3 3Registering Sensors 7 3 4 Installing Wired Detector 8 3 5 Checking Registration 8 3 6 Deleting Registered Key...

Page 4: ...s PROG to save using this way can set C S Account in Pry 7 or other private phone No press the registered key fob ESC key to exit To set C S phone number 1 To register Key fobs 2 To register Detectors 3 To set Zone type 4 To set System configuration 5 To set C S phone NO and site code 1 OVERVIEW 1 1 Introduction 1 Blue backup LCD display everything you want to konw about the panel 2 Full complianc...

Page 5: ...the Alarm Signals from the various Detectors It also contains the central Station communicator and By directional Audio Verification mechanism Everything you need to know about the security system is displayed on the panel keypad LCD The zones 24 Hours Armed Part armed Disarmed and the important Messages regarding system status are displayed on the LCD screen See section 2 1 and 2 2 Wireless Remot...

Page 6: ...tect the particular frequency and then transmitting an alarm signal to the control panel 1 2 3 4 5 6 7 1 1 watchdog zone 0 not a watchdog zone 2 1 exit delay 0 no exit delay 3 1 entry delay 0 no entry delay 4 1 24 hours zone 0 not 24 hours zone 5 1 sounder when alarming 0 silent when alarming 6 1 armed zone 0 part armed zone 7 1 sensor in the zone 0 no sensor in the zone Zone 1 selected 2 DESCRIPT...

Page 7: ...ng system status appear on the LCD screen LOG M D H M D 2 2 The LCD Character details and description 2 2 1 The panel LCD screen whole information shows as follows Figure 23 Detector No 2 in zone 3 is low voltage LOG DIS PART ARMED WatchDog M D H M D B When the panel is in the Armed PART Armed mode if the detector such as PIR detects itself being low voltage the panel will sound a beep every secon...

Page 8: ... is transferred to the C S the operator then has access to the customer details address name phone numbers 2 2 2 When the panel is set in the away armed mode the LCD screen will show the following ARMED key holders etc He also has audio access to the premises He can Listen in or Speak to the occupants this will allow the C S operator to request a pre arranged password to confirm the identity of th...

Page 9: ... fob will still be sounder alarm if it is set with sounder alarm 4 9 Access the Control Panel from a remote telephone mobile or land line The Remote Control enables the use of the land line phone or mobile phone to remotely control panel Call the phone number of the line connected to the alarm panel the panel will answer the call after 1 to 8 rings programmable When the panel answers the call ente...

Page 10: ...ows particular detectors in each Zone to be local alarm only or local alarm and transmit alarm information to the C S each detector can be configured differently e g local Alarm only or local Alarm and C S function door bell function or in the case of Key Fob Request Assistance with without sounder How to set the function press Sensor key and appears on the LCD Press registered Key Fob or entering...

Page 11: ...n the keypad a series of appear on the LCD Enter the PIN code or press the Disarm key on a registered key fob and the word Sensor will appear on the LCD Trigger the detector you wish to register the panel will receive the detectors code and the word CODE will appear on the LCD Pressing a numeric key 1 to 8 on the keypad will select the zone you wish to allocate the detector e g Pressing No 3 on th...

Page 12: ...e No 2 detector in Zone 3 If no further actions take place the panel will automatically return to normal state after approximately 30 seconds Otherwise at the end press Dis Arm key on a registered Key Fob to return the panel to normal state 3 8 The Zone Setting and Allocation The alarm system has 8 zones which can be configured depending on your requirements The Factory Default Zone configuration ...

Page 13: ...d PIN code and the word Sensor will appear on the LCD Pressing the key on the Keypad the LCD will show the words Zone type pressing No1 to 8 numeric key to select corresponding zone then pressing the 0 or 1 numeric Keypad to configure all the fields in this zone At the end press the PROG key to complete and save operation By way of example below is configured as follows Zone 7 selected is a Watchd...

Page 14: ...04 20 seconds 02 Entry delay time delay alarm The time is double digit XX The actual time is the product of XX times 5 The initialization value is 06 30 seconds 03 Sounder run time The time is double digit XX The actual time is the product XX times 20 The initialization value is 06 120 seconds 04 Watchdog time The unit time is hours The factory default value is 12hours 05 Watchdog start and stop t...

Page 15: ...is required within 2 5 seconds after transmitting data to the C S the Panel Will receive the SPEAK request from C S If it is not required the panel hangs up automatically ALM phone line cut_off alarm Figure15 The LCD display when the phone line is cut 13 Engineer Option Listen to dial out DTMF 0 NO 1 YES This option will Automatically extinguish when the panel is closed or on the hour Default 0 14...

Page 16: ...e account code using the numeric keypad on the panel this is normally a 4 Digit Code called site code Press Prog key to store the programmed number If no further actions take place the panel will automatically return to normal state after approximately 30 seconds Otherwise at the end press the Dis Arm key on a registered Key Fob to return the panel to normal state 3 12 Deleting Zones How To Delete...

Reviews: