![Argo ACS100 Service Manual Download Page 44](http://html.mh-extra.com/html/argo/acs100/acs100_service-manual_2967426044.webp)
1-
41
1
1-2. Major Component Specif cations
(A) Indoor Units
Wall-Mounted Type
AWS36PH
/
AWS45PH
MODEL No.
AWS36PH
/
AWS45PH
Source
220 - 230 - 240 V, 1 phase, 50/60 Hz
Controller P.C.B. Ass'y
POW-KR74GXH56 (Microprocessor)
Fan (Number...diameter, depth)
Cross - flow (1...ø90, L746)
Fan motor
Model...Nominal output
W
UF4Q-31G5P...12W
Source
220 - 230 - 240 V, 1 phase, 50/60 Hz
No. of pole...rpm (230V, High)
rpm
4P...1,205
Coil resistance
(Ambient temperature 20°C)
Ω
BRN–WHT : 490.5
ORG–YEL : 39.18
WHT–VLT : 78.43
YEL–PNK : 213.5
VLT–ORG : 62.63
Safety device
Operation temperature
(17AM033E5-4)
Open °C
130 ± 5
Close °C
83 ± 15
Operation temperature
(9700k211-215)
Open °C
130 ± 8
Close °C
79 ± 15
Run capacitor
VAC, µF
440 VAC, 1.0 µF
Electronic expansion valve
Coil
–
Coil resistance (at 20°C)
Ω
–
Valve body
–
Heat Exchanger
Coil
Aluminium plate fin / Copper tube
Rows...fin pitch
mm
2...1.3
Face area
m
2
0.231
Panel
Model No.
–
Dew proof heater
–
Auto louver motor
–
Coil resistance (at 20°C)
Ω
–
Drain Pump
Rated
VAC, W
–
Total head & capacity
–