1
4
3
2
5
A
EL7-I - -
1
2
3
96
105
145
A
C
1
2
3
4
5
EL7-I_Pokyny_Instructions_Hinweise_19151_1en_de_cz_04/2021
Page 6
www.argo-hytos.com
3.2 Connecting plug:
The electronics are connected using a
5 pin M12x1
connecting plug (female). The recommended minimum cross section of the supply wires
is 0.75 mm
2
, cable shielding is recommended. The connecting plug is not part of the delivery, it can be ordered according to the
K_KM_ha8008
datasheet.
Connector connection
Pin No.
Input analogue signal
Connection to CAN bus line
1
Supply vUcc
Supply vUcc
2
Supply GND
Supply GND
3
Input command signal
CAN GND
4
Input signal GND
CAN HIGH
5
Output Uref = 5 V DC
CAN LOW
Digital electronic control unit
Design type
Integrated on the valve
Input command signal
analogue
digital CANopen
Type of controlled valve
single solenoid valve
double solenoid valve
valve with bipolar linear motor
Distance between the fixing screws of ECU and
connector plug of the second coil
(for doble solenoid valves only)
96 mm (for directional control valve size 04)
104.5 mm (for directional control valve size 06)
144.5 mm (for directional control valve size 10)
Ordering Code
1
– product code according to the type key
2
– permissable supply voltage range
3
– SAP order number
4
– serial number
5
– QR code for more information on manufacturer’s website
Type label -
located on the side
3.3 Product labeling
Types of integrated electronic control unit
Electronics
Controlled valve
EL7-IA-1
Sigle solenoid valve with an analogue input command signal
EL7-IC-1
Single solenoid valve and a connection to CAN bus line
EL7-IA-3
Valve with a bipolar linear motor and an analogue input command signal
EL7-IC-3
Valve with a bipolar linear motor and a connection to CAN bus line
EL7-IA-2-96
Double solenoid valve size 04 with an analogue input command signal
EL7-IA-2-105
Double solenoid valve size 06 with an analogue input command signal
EL7-IA-2-145
Double solenoid valve size 10 with an analogue input command signal
EL7-IC-2-96
Double solenoid valve size 04 and a connection to CAN bus line
EL7-IC-2-105
Double solenoid valve size 06 and a connection to CAN bus line
EL7-IC-2-145
Double solenoid valve size 10 and a connection to CAN bus line
Length of connecting cable
(for double solenoid valves only)
defined as a distance between the fixing screws of ECU and connector
plug of the second coil (see picture)
A
96 mm (3.78 in) - for directional control valve size 04
104.5 mm (4.11 in) - for directional control valve size 06
144.5 mm (5.69 in) - for directional control valve size 10
Summary of Contents for EL7-I Series
Page 2: ...EL7 I_Pokyny_Instructions_Hinweise_19151_1en_de_cz_04 2021 Page 2 www argo hytos com...
Page 22: ...EL7 I_Pokyny_Instructions_Hinweise_19151_1en_de_cz_04 2021 Page 22 www argo hytos com...
Page 42: ...EL7 I_Pokyny_Instructions_Hinweise_19151_1en_de_cz_04 2021 Page 42 www argo hytos com...