![AREBOS AR-HE-KV2300W/B Original User Manual Download Page 16](http://html1.mh-extra.com/html/arebos/ar-he-kv2300w-b/ar-he-kv2300w-b_original-user-manual_2966397016.webp)
Original User Manual
–
A
REBO
S Convector 2300W
16
Auto Power Off panel
The device is turned on.
•
Press the Timer button (14).
•
Use the Timer (14) button to select the desired number of hours. The value range is between
1 and 24.
The number of hours is displayed flashing in the Timer (10) indicator.
The desired time until automatic shutdown is saved as soon as the indicator Timer (10) stops
flashing.
The time to power off is displayed and counted down in the Timer (10) display.
The device switches to standby mode.
Hint!
for automatic shutdown:
•
Manually turning off the device disables automatic power off.
•
If you select the number of hours 0, the timer is switched off.
Decommissioning
Warning!
from electrical voltage!
Do not touch the power plug with damp or wet hands.
•
Turn off the device by switching the power button to position 0.
•
Unplug the power cord from the power outlet by touching it on the power plug.
•
3. Allow the device to cool down sufficiently.
•
4. Clean the device according to the chapter Maintenance.
•
5. Store the device according to the chapter Storage.
5
Errors and malfunctions
Warning! from electrical voltage! Activities that require the opening of the device may only be
carried out by authorized specialist companies or by AREBOS.
The device was tested several times during production for proper functioning. Should malfunctions
nevertheless occur, check the device in the following list.
The device does not start:
•
Check the power connection.
•
Check the power cord and power plug for damage. If you notice damage, do not try to get the
device back up and running. Order a new power cord with power plug from AREBOS and
replace the defective power cord with power plug.
•
Check the on-site network protection.
•
The room thermostat may be defective. Have a defective room thermostat replaced by a
specialist electrical company.
•
Wait 10 minutes before restarting the device. If the device does not start, have an electrical
inspection carried out by a specialist company or by AREBOS.
The device is turned on, but it does not heat:
•
The heating resistance may have burned through. Have a defective heating resistor replaced
by an electrician.
•
The room thermostat may be defective. Have a defective room thermostat replaced by a
specialist electrical company.
•
The room thermostat may be defective. Have a defective room thermostat replaced by a
specialist electrical company.