PMX-4EX-SA Manual
page 78
Rev 3.11
Figure 7.25
a.
Length/Pulse
– Select relationship between number of
pulses and length of movement in terms of inch or
millimeter.
b.
Max Stroke Length
– The largest allowable stroke
length. This will affect the scaling of the DXF viewer box
c.
HS/LS/ACC
- High Speed, Low Speed and Acceleration
settings
d.
Pen Up Routine
– The routine when the XY axis is not in
position
e.
Pen Down Routine
– The routine when the XY axis is in
position
f.
Save & Close
parameters and exit setup
2.
Load DXF File
– browse your PC for a 2D DXF file to load into
the DXF Viewer
3.
Convert File
– Convert the loaded DXF file into PMX-4EX-SA
compatible motion commands. The result will be loaded into the
Motion Conversion Program box. The conversion scaling and
speed will depend on the parameters set in the Parameter setup
box.