5.2.2. Communication Port Settings
The PMX-4EX-SA has the communication port settings shown in table 5.0.
Parameter
Setting
Byte Size
8 bits
Parity
None
Flow Control
None
Stop Bit
1
Table 5.0
PMX-4EX-SA provides the user with the ability to set the desired baud rate of the
serial communication. In order to make these changes, first set the desired baud
rate by using the
DB
command.
Return Value
Description
1
9600
2
19200
3
38400
4
57600
5
115200
Table 5.1
To write the values to the device’s flash memory, use the
STORE
command.
After a complete power cycle, the new baud rate will be written to memory. Note
that until a power cycle is completed, the settings will not take effect.
By default, the PMX-4EX-SA has a baud rate setting of
9600 bps.
5.2.3. ASCII Protocol
The following ASCII protocol should be used for sending commands and
receiving replies from the PMX-4EX-SA. Details on valid ASCII command can be
found in section 8.