![Arctic Cat 2010 1000 H2 TRV Operator'S Manual Download Page 77](http://html.mh-extra.com/html/arctic-cat/2010-1000-h2-trv/2010-1000-h2-trv_operators-manual_2965263077.webp)
75
GENER
A
L MAINTENAN
CE
NOTE: If the battery voltage is
11.5 DC Volts or less, some char-
gers may “cut off” and fail to
charge. If this occurs, connect a
fully charged booster battery in
parallel (positive to positive and
negative to negative) for a short
period of time with the charger
connected. After 10-15 minutes,
disconnect the booster battery
leaving the charger connected and
the charger should continue to
charge. If the charger “cuts off,”
replace the battery.
8. After charging the battery for the
specified time, remove the battery
charger and allow the battery to sit
for 1-2 hours.
9. Connect the multimeter and test
the battery voltage. The meter
should read at least 12.5 DC Volts.
If the voltage is as specified, the
battery is ready for service.
NOTE: If voltage in step 9 is below
specifications, charge the battery an
additional 1-5 hours; then retest.
Recheck electrolyte level and the
battery is ready for service.
10. Place the battery in the battery
compartment; then coat the battery
posts and cable ends with a light
coat of multi-purpose grease.
11. On the 400, connect the vent hose.
12. Connect the battery cables (posi-
tive cable first); then install the
battery hold-down.
NOTE: Arctic Cat highly recom-
mends all ATV batteries be con-
nected to a maintenance charger
during storage or any extended
period of non-use. The charger
MUST have an automatic float,
storage-safe, or pulse mainte-
nance mode to avoid battery dam-
age due to long-term
overcharging. To connect the
maintenance charger, use any of
the following procedures.
A. Remove the battery cover;
then connect the charger leads
(positive cable first) directly to
the battery.
B. Locate the rear accessory con-
nector and connect the charger
leads (positive cable first)
directly to the connector.
C. Using an appropriate adapter,
connect the charger to any DC
power outlet.
Battery Charging Chart
(Constant-Current Charger)
Battery
Voltage (DC)
Charge
State
Charge Time
Required
(at 1.5-2.0
Amps)
12.5 or more
100%
None
12.2-12.4
75%-99%
3-6 hours
12.0-12.2
50%-74%
5-11 hours
11.0-11.9
25%-49%
13 hours
(minimum)
11.5 or less
0-24%
20 hours
(minimum)
CAUTION
Before installing the battery, make
sure the ignition switch is in the
OFF position.
CAUTION
Connecting cables in reverse (pos-
itive to negative and negative to
positive) can cause serious dam-
age to the electrical system.
Summary of Contents for 2010 1000 H2 TRV
Page 89: ...87 MAINTENANCE RECORD DATE MILEAGE SERVICE PERFORMED NOTES ...
Page 90: ...88 NOTES ...
Page 99: ...97 NOTES ...
Page 100: ...98 NOTES ...
Page 101: ...99 NOTES ...