4.
If you have a pair of gates then connect the slave to the Master Unit with 2 core
Flex/Cable (Max load 8 Amp at 12 Volts) (See Figure 3). The LI-2B operators are set
in the factory for a “Standard Installation” with the Master placed on the LEFT HAND
SIDE (From the inside looking out). If the Master has to be located on the right then
the motor wires need to be reversed. To accomplish this, locate the connection blocks
for each motor on the Circuit Board. Swap the BROWN and BLUE wires for Motor 1
and Motor 2 (See Figure 3)
5.
The gate bracket should be positioned so the arms are ALMOST in a straight line
when the gates are closed (See figure 4). To check the location of the gate brackets,
first disengage the Main arm from the drive shaft (using the spanner provided,
unscrew the bolt until the arm swings freely) THEN CLAMP THE GATE BRACKET IN
POSITION. Open and close the gate to ensure the gate bracket is appropriately
located.
LI-2B Installation Manual