Installation
7.0 Electrical Connections
The
22-DVIM22LN-1
may be wired to a thermostat, wall switch, or third party remote control. An optional variable 6 speed fan kit is
available from your local authorized Archgard dealer. Do not cut or remove the grounding prong from the main power supply plug on the
optional fan kit.
CAUTION:
Label all wires prior to disconnection when servicing.
NOTE:
This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes,
with the National Electrical Code, ANSI / NFPA 70, or the Canadian Electrical code, CSA C22.1.
Before you begin:
•
Flip Down the Control access cover (See
Section 6.4
)
To connect a thermostat or wall switch to the fireplace:
Step 1:
Remove the shielding from the ends of the household
wiring. See
Figure 7.0.02
for recommended wire specifications.
Thermostat / wall switch wire table
Recommended Maximum Lead Length for two wires.
Wire Size
Max. Length
14 GA.
50 Ft. (15.24 M)
16 GA.
32 Ft. (9.75 M)
18 GA.
20 Ft. (6.9 M)
20 GA.
12 Ft. (3.65 M)
22 GA.
9 Ft. (2.74 M)
Figure 7.0.01:
Figure 7.0.02:
Step 2:
Run the wire through the opening on either side of the
fireplace. Always keep the wire low, away from the firebox.
Figure 7.0.03:
Step 3:
Connect the wire to the leads on the valve.
Figure 7.0.04:
Note:
See
Figure 20.13.01
for a wiring diagram including the wall
switch or optional thermostat.
Note:
Wall switches, thermostats, or remote controls are not
included with the fireplace and are not covered under warranty.