background image

Software rel. 1.0x

BRAVO 140 SERIES MONITOR

02

INSTALLATION, USE AND MAINTENANCE

46714221

Summary of Contents for BRAVO 140 SERIES

Page 1: ...Software rel 1 0x BRAVO 140 SERIES MONITOR 02 INSTALLATION USE AND MAINTENANCE 46714221...

Page 2: ...rt of the equipment to which it refers and must accompany the equipment in case of sale or change of ownership Keep it for future reference ARAG reserves the right to modify the specifications and ins...

Page 3: ...control unit and services 10 6 2 Connecting the valves 10 6 3 Connecting the sensors 11 6 4 Ultrasonic sensors 12 6 4 1 Mounting the sensors to the tractor 13 6 4 2 Distance between sensors and rows...

Page 4: ...n 21 10 6 Manual operation 21 10 7 Spraying data 22 10 7 1 Sprayed trees count 22 11 Maintenance Diagnostics Repairs 23 11 1 Errors during operation 23 11 2 Test Menu 23 11 3 Troubleshooting 24 12 Tec...

Page 5: ...to identify special instructions for specific models LIABILITY The installation technician is responsible for implementing the installation procedure in a professional manner so as to guarantee perfe...

Page 6: ...sence of a tree needing spraying in this way Bravo14x allows you to spray only where needed and not in between plants This device is designed to work on agricultural machinery for crop spraying applic...

Page 7: ...ead to its controls being accidentally actuated Install the unit is a visible position within easy reach by hand bear in mind that the monitor should not obstruct the operator s freedom of movement or...

Page 8: ...URE TO FOLLOW ALL THE SAFETY INSTRUCTIONS GIVEN IN THE CONTROL UNIT S MANUAL 5 CONNECTING THE MONITOR TO THE MACHINE 5 1 General precautions for cable runs Securing the cables Secure the cables so tha...

Page 9: ...get flat if Bravo 14x stays on for a long time if the engine is not running ensure monitor is off in case of long machine stops with engine stopped Power supply must be connected as shown in Fig 3 FUS...

Page 10: ...the control unit Make sure that it is correctly fitted and turn the collar clockwise until it locks in place 6 2 Connecting the valves All valve connectors must be equipped with gaskets before install...

Page 11: ...the services Item Main connection US1 US2 Ultrasonic sensors S Speed sensor 1 2 Section valves Use ARAG sensors use of unsuitable sensors or sensors not provided by ARAG automatically voids the warra...

Page 12: ...k when ultrasonic sensors code 46713000 100 sold sepa rately are connected Always set sensors in front of leaves at such a height that they can detect the wider area A Fig 6a avoid brushwood Fig 6b or...

Page 13: ...sor corret position according to tree height install and secure them on the machine as described in the attached instruction sheet CAUTION the sensors must always be mounted parallel to the ground and...

Page 14: ...en sensors and rows is too wide Bravo 14x can detect a target that is beyond the trees and thus spray unrequired areas Fig 8a to fix this just decrease sensors range Fig 8b Fig 8a Fig 8b Monitor corre...

Page 15: ...ata RIGHT boom control Only when speed sensor is ENABLED Only when speed sensor is DISABLED 7 3 Display 1 Speed simulator ON only when speed sensor is DISABLED 2 Speed 3 Active operating mode A Automa...

Page 16: ...ion of the treatment product This must be done once only when installing the monitor 9 1 Pre programming tests and checks Before programming the monitor check that all components are correctly install...

Page 17: ...age Enabled Disabled DEF Disabled Speed sensor EU l ha km h m cm imp US gpa h mp ft in pls DEF EU Unit of measure Dist sens sect Dist sens sect 0 00 99 99 m DEF Dist sens sect 2 50 m 8 ft Power sup al...

Page 18: ...c ULTRASONIC CONTROLLER Auto 1 3 1 3 2 4 Set speed sensor Disabled no speed sensor installed Monitor will calculate boom opening closing time according to the speed set by operator simulated speed Par...

Page 19: ...The monitor will show the number of cm inches per pulse Wheel constant has been stored Take measurement with the tyres at operating pressure This test must be performed on medium hard terrain For app...

Page 20: ...distance speed sensor ENABLED 10 3 Sensitivity 10 4 Spraying data reset optional 10 7 Tab 10 10 2 Machine speed simulated S 5 km h A 3 Trs Ok Esc ULTRASONIC CONTROLLER Auto 2 2 1 3 Set machine speed S...

Page 21: ...sary settings prior to spraying Select automatic mode A Enable required booms Drive to where the row starts and switch the pump on Start spraying When this symbol is on boom is ACTIVE press and hold k...

Page 22: ...th sides of the tractor SIDE B When one side of a row is treated SIDE A Bravo 14x calculation considers half a unit for each sprayed tree for example in the instance shown in Fig 12 Bravo 14x calculat...

Page 23: ...VALVSX KEY VALVDX KEY OK KEY AUTO KEY Esc Auto Ok ULTRASONIC CONTROLLER Auto Menu Test Ok Auto Clean only with a soft wet cloth DO NOT use detergents or aggressive products DO NOT aim water jets direc...

Page 24: ...heck wheel constant Par 9 7 and row distance settings Par 10 3 Displayed sprayed trees count does not match the actual number of trees sprayed Ultrasonic sensors do not work correctly Check ultrasonic...

Page 25: ...hine speed US inches imp Sens sect dist Distance between ultrasonic sensors and booms 0 00 99 99 EU m Used to calculate boom opening and closing US ft Power supply alarm Type Available options Disable...

Page 26: ...tallation and regulation damage or malfunction caused by the lack of ordinary maintenance such as cleaning of filters nozzles etc anything that can be considered to be normal wear and tear 3 Repairing...

Page 27: ...14X codice 46714XXX risponde ai requisiti di conformit contemplati nelle seguenti Direttive Europee 2004 108 CE e successive modificazioni Compatibilit elettromagnetica Riferimenti alle Norme Applicat...

Page 28: ...ITALY Via Palladio 5 A Tel 39 0522 622011 Fax 39 0522 628944 www aragnet com info aragnet com Only use original ARAG accessories and spare parts to maintain safety conditions foreseen by the construct...