![AR 350AH1A Operating And Service Manual Download Page 40](http://html1.mh-extra.com/html/ar/350ah1a/350ah1a_operating-and-service-manual_2962316040.webp)
Model 350AH1A
24
Rev B
2.6.6.11
RF Gain
Query to get the RF gain.
Syntax:
RFG?
Parameters:
None
Response Format:
RFG=<space>x
Where:
x = 0000 to 0100
Example:
To find out the RF gain of the amplifier, send the following query:
RFG?<LF>
Response:
RFG=<space> 0075<LF>
(75% Gain)
2.6.6.12
Output Phase Selection
Command/query to set and/or get the output phase with respect to the input.
Syntax:
PHASEx
Parameters:
Value(x):
0 = Output phase is the same as input signal
180 = Output phase is 180° out of phase from input signal
Syntax:
PHASE?
Response Format:
PHASE=x
Where:
x = 0 or 180
Example:
To find out the output phase, send the following query:
PHASE?<LF>
Response:
PHASE=0<LF>