![AR 350AH1A Operating And Service Manual Download Page 19](http://html1.mh-extra.com/html/ar/350ah1a/350ah1a_operating-and-service-manual_2962316019.webp)
Model 350AH1A
Rev B
3
1.5.2
AC Power
The Model 350AH1A is designed for a primary power input of 90–260 VAC, 47/63 Hz, single phase.
CAUTION:
Dangerous voltages are present in the amplifier whenever it is plugged
into an AC outlet. Always disconnect the AC power line to the amplifier
before servicing the unit.
1.6 CONNECTORS
1.6.1
Amplifier Input Connector
The RF input connector for the amplifier is located on the left side of the control panel. It is a female, Type
BNC connector.
1.6.2
Amplifier Output Connector
The amplifier output connector is a 5-way binding post located on the right side of the control panel.
1.6.3
Safety Interlock Connector
Located on the left side of the rear panel, as viewed from the rear, are the remote interface connectors and
safety interlock connectors. The 15-pin D-sub miniature female safety interlock connector provides two
separate interlock loops. Pins 1 and 8 are used for situations where the amplifier can be left on, but forced into
STANDBY mode. This interlock is called Inhibit Interlock. Pins 10 and 14 are used for situations that
demand the safest possible condition, with the AC power to all main circuits disconnected. This interlock is
called AC Interlock. Both loops must be closed, or jumpered, for normal operation.
1.6.4
Communications Connectors
1.6.4.1
RS232 Wire
Standard 9-pin D-subminiature female connector is provided on the rear panel.
1.6.4.2
IEEE-488
A standard 44-pin female GPIB panel connector is provided on the rear panel.
1.6.4.3
USB
A standard USB-B connector is provided on the rear panel.