Model 5000A225A
Rev B
33
n is the two digit MPA number which was selected with the Initiate MPA Coolant
Temperature and Transistor Currents Command.
If n is 00 then the data in the buffer has already been read and the Initiate MPA Coolant Temperature and
Transistor Currents Command must be issued again.
T
=
0.0 to 999.0 (temperature of the MPA coolant in Celsius)
a1 to d4 = 0.0 to 99.9 (transistor current in Amps)
a1 to a4 are transistors 1 to 4 of module 1.
B1 to b2 are transistors 1 to 4 of module 2.
C1 to c4 are transistors 1 to 4 of module 3.
D1 to d4 are transistors 1 to 4 of module 4.
Leading zeroes are read as spaces. (Total return string length is 95 characters)
Example:
To find out the coolant temperature and transistor currents for MPA 1, send MPA01 and
then send the following query.
MPA?<LF>
Response:
MPA01=80.5, 5.4, 5.3, 5.4, 5.4, 5.5, 5.6, 5.4, 5.3, 5.4, 5.3, 5.4, 5.4, 5.5, 5.6, 5.4, 5.3<LF>
2.4.2.6.18
Remote Operating Timeout
Command to set the period between required communications to maintain an RF On state while in remote
mode.
Syntax:
ROPTOx
Parameters:
x = 0 to 500 in seconds
Query:
ROPTO?
Response Format:
ROPTO=x<LF>
Example:
To set the required period between communications that must be maintained once RF On
has been initiated, send the following command.
ROPTO10<LF>
To find out what the period between communications that must be maintained once RF On has been initiated,
send the following query.
ROPTO?<LF>
Response:
ROPTO=6<LF>