Model 5000A225A
Rev B
31
80
0050
MPA2 A1-UC
Module A1 Under Current
On
MPA 2
81
0051
MPA2 A2-UC
Module A2 Under Current
On
82
0052
MPA2 A3-UC
Module A3 Under Current
On
83
0053
MPA2 A4-UC
Module A4 Under Current
On
84
0054
MPA2 A1-OC
Module A1 Over Current
On
85
0055
MPA2 A2-OC
Module A2 Over Current
On
86
0056
MPA2 A3-OC
Module A3 Over Current
On
87
0057
MPA2 A4-OC
Module A4 Over Current
On
90
005A
MPA2 Coolant Lvl
Coolant Level
Off
91
005B
MPA2 PS2
Power Supply 2
Off
98
0062
MPA2 Comb Therm
Combiner Thermal
Off
100
0064
MPA2 A4-TH
Module A4 Thermal
Off
101
0065
MPA2 A3-TH
Module A3 Thermal
Off
102
0066
MPA2 A1-TH
Module A1 Thermal
Off
103
0067
MPA2 A2-TH
Module A2 Thermal
Off
104
0068
MPA2 Flow
Coolant Flow (Driver MPA)
Off
105
0069
MPA2 485 Error
MPA Internal RS-485 Communication Bus Error
On
107
006B
MPA2 Coolant Tmp
Coolant Temperature
Off
Example:
To find out what faults have occurred, send the following query.
FSTA?<LF>
Response:
FSTA=<space>0003<LF>
(Interlock Fault)
2.4.2.6.14
Operating Hours (RF On)
Query to get the RF On operating hours.
Syntax:
OH?
Parameters:
None
Response Format:
OH=x<LF>
Where:
x
=
0
to
100000
Units are Hours. Values can be up to six digits in length. Leading zeros are read as
spaces.
Example:
To find out the RF On operating hours, send the following query.
OH?<LF>
Response:
OH=<space><space><space><space>37<LF>
(The system has spent 37 Hours in an RF On state)