MAINTENANCE MANUAL
AQUILA AT01
A
1.
Empennage - Inspect complete surface of the vertical and
X
horizontal stabilizers, the elevator and the rudder for
dents, cracks, holes and delamination.
2.
Rudder hinge, elevator hinge and bellcranks - Check brackets
X
and bellcranks for security of attachment and corrosion.
Examine bearings for binding and excessive play. Check hinge
bushings and replace if necessary. Check correct safetying of
the lower rudder pivot pin with castellated nut and cotter pin.
Page 12
05-20-00
Maintenance Checks
No.
Reference
Interval
Initials
100h
other
Empennage, Elevator, Rudder
16.09.19
No.
Wings, Ailerons, Flaps (Cont.)
Reference
Interval
Initials
100h
other
8.
Flap hinges - Check play. Maximum play approx.:
X
- Axial ± 0,30 mm (± 0.01 in.)
- Radial ± 0,30 mm (± 0.01 in.)
Measure the play in the flap control system at the flap trailing
edge, at the inboard flap end. Max. play allowed with flaps in
take-off and landing positions: ± 5 mm (0.2 in.). No play with
flaps retracted.
9.
Flaps and ailerons - Check that the gap between fuselage and
X
flaps, between flaps and ailerons, and at the outboard end of
the ailerons is at least 2 mm ( 0.08 in.).
10.
Stall warning system - Check for condition and proper
X
operation.
11.
For serial numbers from AT01-100 to AT01-126:
57-10-00
annual
Bonding between wing spar and upper shell - Check
SB-AT01-002
condition.
12.
Navigation / strobe lights - Check operation, condition
33-40-00
X
of glass, and security of attachments.
13.
Inner fuel tank ribs - Check connection of fuel and vent
28-10-00
annual
lines to the fuel tank and the flange gasket of the fuel level
28-20-00
sensors for signs of leakage.
28-40-00
14.
Fuel vent lines - Check for blockage.
X
15.
Fuel tank drain valves - Check for correct function and
X
leakage.
16.
Fuel outlet screens - Check for damage. Clean if necessary.
1000h
17.
Fuel filler caps - Check for proper function and leakage.
X
18.
Tank inlet and upper wing shell in the fuel tank area - Check
SB-AT01-027
annual
sealing of the bore hole in the tank inlet. Check wing skin for
bubble formation or bulging.
19.
Tie-down points - Check thread and structure around the tie-
10-20-00
X
down attach points for any damage.
Summary of Contents for AT01
Page 2: ...MAINTENANCE MANUAL AQUILA AT01 A ...
Page 4: ...MAINTENANCE MANUAL AQUILA AT01 A ...
Page 6: ...MAINTENANCE MANUAL AQUILA AT01 A ...
Page 9: ...MAINTENANCE MANUAL AQUILA AT01 A CHAPTER 5 TIME LIMITS MAINTENANCE CHECKS ...
Page 10: ...MAINTENANCE MANUAL AQUILA AT01 A ...
Page 12: ...MAINTENANCE MANUAL AQUILA AT01 A ...
Page 14: ...MAINTENANCE MANUAL AQUILA AT01 A ...
Page 18: ...MAINTENANCE MANUAL AQUILA AT01 A Maintenance Checks ...
Page 46: ...MAINTENANCE MANUAL AQUILA AT01 A Maintenance Checks ...