MAINTENANCE MANUAL
AQUILA AT01
A
37.
Carburetors - Removal/assembly of the two carburetors for
Rotax Heavy MM
200h
carburetor inspection.
73-00-00 3.1)
2)
38.
Carburetors - Check the free movement of the carburetor
R912* 12-20-00 10)
X
actuation (throttle lever and starting carburetor). Check that
the Bowden cable allows full travel of the throttle lever from
stop to stop. Check Bowden cables for bulging with control
lever in the full throttle position. Adjust throttle control if
76-00-00
necessary. Lubricate carburetor throttle shaft.
12-22-00
39.
Carburetor sockets and drip tray - Inspect the carburetor for
Rotax Heavy MM
200h
damage and abnormalities, check for cracks, wear and good
73-00-00 3.4.3)
condition. Take note of any changes caused by temperature.
SB-912-030
2)
40.
Airbox assy - Check for damage, security of attachment and
X
condition. Inspect connected air hoses for condition and
leakage. Check that the flaps can be moved through their
full arc of travel for hot and filtered ram air.
2)
41.
Air filter - Inspect and clean. Renew if necessary. Clean air
R912* 12-20-00 2)
X
filter casing. Check the drain hole at the bottom of casing
for obstructions or blockage.
2)
42.
Other external engine accessories - Inspect screws and nuts
X
of all other external engine parts and accessories for tight fit.
Inspect safety wiring if applicable, replace as necessary.
2)
43.
Engine mounts (manufactured by ROTAX and AQUILA) -
R912* 12-20-00 3)
X
Check mounts for deformation, cracks, corrosion,
SB-912-028
security and damage from heat. Check mounting bolts for
SB-AT01-022
condition and correct torque value.
At engine (4 bolts M10): 40 Nm (354 in.lbs)
At shock mounts (4 bolts M10): 25 Nm (221 in.lbs)
At firewall (4 bolts M10): 30 Nm (266 in.lbs)
Inspect shock mounts for deterioration.
2)
1)
44.
Engine test run - Attach cowling and perform an engine test
17-10-00
X
50h
run as described above. After engine test run, re-tighten oil
05-20-00
filter by hand and examine engine and engine compartment
R912* 12-10-00 8)
for signs of leakage. Compare results with first engine test
run. Check oil level, replenish as necessary.
Page 7
05-20-00
Maintenance Checks
No.
Engine (Cont.)
Reference
Interval
Initials
100h
other
1) If more than 30% of operation hours have been flown with leaded fuel e.g.: AVGAS 100LL.
2) Check has to be carried out every 100 hours of operation or 12 month, whichever comes first.
16.09.19
Summary of Contents for AT01
Page 2: ...MAINTENANCE MANUAL AQUILA AT01 A ...
Page 4: ...MAINTENANCE MANUAL AQUILA AT01 A ...
Page 6: ...MAINTENANCE MANUAL AQUILA AT01 A ...
Page 9: ...MAINTENANCE MANUAL AQUILA AT01 A CHAPTER 5 TIME LIMITS MAINTENANCE CHECKS ...
Page 10: ...MAINTENANCE MANUAL AQUILA AT01 A ...
Page 12: ...MAINTENANCE MANUAL AQUILA AT01 A ...
Page 14: ...MAINTENANCE MANUAL AQUILA AT01 A ...
Page 18: ...MAINTENANCE MANUAL AQUILA AT01 A Maintenance Checks ...
Page 46: ...MAINTENANCE MANUAL AQUILA AT01 A Maintenance Checks ...