background image

 

 

 

 

6

 

7

 

8

 

 

 

The Aquavolta 

®

Monmi Tec (1) is packed in a cardboard box. Please keep this carton after 

unpacking for possible sending in for inspection. The appliance (1) does not have an internal 

water filter. In case of doubtful water we recommend to install a pre-filter suitable for your 

water supply situation in the supply line or to use the option to supply drinking water from a 

canister.... 

 

As accessories you will find: 
• 

¼ 

inch hoses with quick couplings and shut-off valve for inflow and outflow. (2) 

•  Intake filter for water supply from canisters (2) 
•  5 Litre double distilled water (laboratory water) (4) 
•  Adapter set (5a) for connecting the diverter valve with aerator (5b) (illustration similar) 
•  Angle shut-off valve 3/8 inch with regulating lever (6) for connecting the Aquavolta 

®

Monmi 

Tec or a pre-filter to the angle valve. 

•  Filling funnel for laboratory water (7) 
•  Suction nipple for fixing the waste water hose (8) 

 

Scope of 

delivery

 

4

 

Lab-

 

Water 

lit5res

 

1

 

5a

 

5b

 

 

 

3

 

 

2

 

Summary of Contents for Monmi-Tec HIM 3.0 ppm

Page 1: ...MONMI TEC HIM ppm3 0 H Water2 Infusion Machine Hydrogen enrichment of tap water without electrode contact Technology Sensation 2022 Manual from Karl Heinz Asenbaum...

Page 2: ...redox potential The lower the redox potential the higher the readiness of the water to give up electrons For every volt0 018 18 millivolts of lower redox potential this readiness doubles AquaVolta has...

Page 3: ...charged electron This smallest of all atoms is also called nascent hydrogen This means hydrogen in the birth phase because an H atom does not stay alone for long but then forms with a second H atom wh...

Page 4: ...ith higher pressure the process is faster Another trick for acceleration is to increase the contact area between water and gas This is usually achieved by injection nozzles or swirl mechanics and acce...

Page 5: ...re achieved with them They were particularly popular in the USA In Europe they were not very popular because the water ionisers that were widespread here offered similar hydrogen outputs and also made...

Page 6: ...a is a very complex Pressure HIM and you can access the full text via the QR code The core elements are software controlled solenoid valves also invented by Tan Teong Chin a special injection techniqu...

Page 7: ...g plug and quick coupling 14 Water supply options 15 Assembly A with deflector fan 16 Mounting B on angle valve with hole 17 Mounting C with mounting ring 18 Alternative water supply from canister 19...

Page 8: ...t use chemical cleaning agents Never drop the unit Do not expose the unit to direct sunlight or temperatures below or 0above degrees50 C Do not place the unit in damp or dirty rooms Do not place the u...

Page 9: ...om a canister As accessories you will find inch hoses with quick couplings and shut off valve for inflow and outflow 2 Intake filter for water supply from canisters 2 5 Litre double distilled water la...

Page 10: ...nd stops the Hydrogen water flow Note This unit is already sold in the much larger market in China and is therefore still labelled with Chinese characters It only has control buttons2 on the right and...

Page 11: ...11 Nameplate Rear wall mounting...

Page 12: ...boratory water tank PEM H2 cell H2 Gas storage tank Behind H 2 water mixing tank UV Disinfection Drain valve of the H water2 tank Magnetic pre structuring of the tap water Pressure pump Internal struc...

Page 13: ...the OUT socket Main switch connections Note This unit is already sold in the much larger market in China and is therefore still labelled with Chinese characters The function of the inputs outputs is d...

Page 14: ...inserted tube or plug PULL 3 With a little skill you can do it with your fingers If necessary use a small open ended spanner or a fondue fork Please keep the stoppers 4 When you want to put the plugs...

Page 15: ...y a professional It is in the As a rule a hole is also drilled for the inch connection hose through the Kitchen worktop or the edge of the basin required 3 Angle shut off valve B without hole with mou...

Page 16: ...ories and screw it in clockwise including the black rubber seal above 4 Unscrew the union nut from the baffle and slide it over a suitably shortened scissors inch hose Push it onto the nipple and tigh...

Page 17: ...by turning the lever crosswise and opening the knob of the angle valve with the tap closed 5 Insert a suitably cut end of the white hose firmly into the ring coupling of the angle shut off valve Make...

Page 18: ...hose from the outside to the inside through the hole in the mounting ring seal facing down under the sink and place the tap on the mounting ring 7 Now reattach the tap Please carry out the further st...

Page 19: ...ster Then lower the intake filter to the bottom of the canister Then insert a waste water hose into the Waste water outlet second from the top and feed its other end back into the canister The water i...

Page 20: ...19 1 Open front flap by pressing lightly 2 Insert the loose elbow connector firmly 3 Press the front flap back on Preparation for first installation...

Page 21: ...ing counterpressure push on the retaining ring Until overflow 2 Fill laboratory water here with the funnel until it overflows 3 Push both plugs firmly back in 4 Wipe off water residues Filling in the...

Page 22: ...24 V DC 4 A output into the power supply unit input socket on the Monmi Tec unit 3 Connect the power supply unit to the V220 AC socket If necessary use the EU adapter supplied Connection of water supp...

Page 23: ...22 Setting the time...

Page 24: ...s out of the tap 2 Press and hold the left button until HHH is displayed 3 In the next few hours3 5 the display shows the symbols shown below in the order PCHCH 4 At the end of the process the time is...

Page 25: ...utes5 for the replenishing water to recharge with the hydrogen gas 4 To maintain the high concentration of the very volatile hydrogen of 3 ppm use the water as soon as possible after filling 5 You can...

Page 26: ...upply in it must be refilled regularly recommended x2 per week with freshly produced H2 gas from the PEM cell This is triggered by the handling shown above During the refuelling process a little water...

Page 27: ...into the lowest socket Then open the two plugs on the top of the unit The tank will then empty When no more water comes out put the waste water hose back in the second position from the bottom and pl...

Page 28: ...Manufacturer Importer Aquacentrum for Aquavolta Germany Model Aquavolta Monmi Tec HIM Hydrogen water infusion machine Dimensions 38 5 x x28 4 cm13 5 Filter performance Without built in water filter Ca...

Page 29: ...the two year legal warranty All warranty commitments are therefore listed on the purchase receipt invoice from your dealer General sales and service centre Aquacentrum owner Yasin Akg n M nchener Str...