8. Push the brine line into the brineline
connector and secure it by pushing in
the locking clips. Pull the brine line to
see if it is secure.
9.
Secure the flow regulator by installing
the Flow holder with the gasket
mounted on the inner brine tank wall
and align the opening with the holder.
10.
Push the brine line into the white quick
connector inside the brine well.
11. Pull on the brine line to see if it is
secure.
12. Pour in at least two bags (80 lbs) of salt and 5 gallons of tap water into the brine tank.
13. Place the unit in the bypass position. Locate the nearest faucet and remove aerator
(faucet screen) if there are any. Turn the cold water position on at the nearest faucet and
slowly turn on the main water supply. Let the water run for a few minutes or until the
system is free of any air or foreign material resulting from the plumbing work.
14. Make sure there are no leaks in the plumbing system before proceeding and shut off the
nearest faucet when water runs clear.