STEP 6.
System Startup
1.
Flow Meter Indicator
2.
Time of Day
3.
Status
4.
Volume Remaining
5.
Regeneration Mode
Timer
Meter Immediate
Meter Delay
Setting Button
1. Enter into setting menu
2.
Confirm the current setting, and enter into the next step
3.
When used simultaneously with up button, it will enter into master
programming
Up / Down Buttons
1. Adjust current settings
2. Go one step forward or backward
Cycle Button
1. Save the setting and return to service
2.
Enter into queued regeneration mode
3. A long press for 5 - 6 seconds will initiate a immediate regenerate
4. Terminate the current regeneration step and goes to the next step
1. Plug the power transformer into an approved power source. Connect the power cord to
the valve.
2.
When power is supplied to the control, the screen will display the time of day, gallons
remaining and the mode. Press and hold the “Cycle” button. The valve will display “GOTO
BW” and will continue to move until it reaches the backwash system.
3.
Once the valve is in the backwash (BW) cycle the display will show a time value (10),
open the inlet on the bypass valve slowly and allow water to enter the unit. Air from the
tank will begin to push out of the control valve drain. Allow all air to escape from the
unit before turning the bypass fully open. If there is a large “knocking” sound, the water
is being fed too quickly and should be slowed. Once there is a steady stream of water
coming from the system drain with no air coming out, allow water to run to drain for 3-4
minutes or until all media/ resin fines are washed out of the softener which is indicated
by clear water in the drain hose.