MECHANICAL FILTRATION AND REVERSE OSMOSIS MODULES
INSTALLATION AND CONNECTION PROCEDURES
2
The system must be installed in accordance with applicable city, state, and local plumbing codes.
AquaSafe™ is designed to provide years of trouble-free service if properly maintained.
Retain these instructions for future reference.
PREPARATION
1.
CAUTION:
Do not install system on hot water line.
Locate shut off valve on source water line and shut
off water supply.
2. Identify the module type to be installed:
a. Mechanical Filtration: The port at the top
center of the head is blocked.
This unit is shipped fully assembled. Refer to
Section “MECHANICAL FILTRATION
MODULE” on this page for instructions
b. Reverse Osmosis: The port at the top center of
the head has the threaded connection for the
membrane and flow control assembly.
This unit is shipped fully assembled. Refer to
Section “REVERSE OSMOSIS MODULE” on
this page for instructions
c. Ultraviolet: The port at the top center of the
head is open.
This unit is assembled as part of the installation
process. Refer to Section “ULTRAVIOLET
MODULE” on Page 10 for instructions.
INSTALLATION
NOTE:
Item number callouts in the following Installation
Instructions refer to Page 4, Figure 4 unless noted
otherwise.
MOUNTING BRACKET
1. Determine location for brackets that will provide
adequate clearance (Page 1, Step 2).
2. Remove the Mounting Bracket Screws (Item 5) and
pull the Upper Mounting Bracket (Item 6) away
from the Lower Mounting Bracket (Item 7).
3. Pull the module assembly away from the lower
mounting bracket and set the module assembly
aside.
4. Attach the Mounting Brackets (Item 7) to the wall on
6” centers.
MECHANICAL FILTRATION MODULE
NOTE:
Use thread sealing tape (P/N 35700002) on
male threaded connections.
1. Install lower brackets as instructed in Section
“MOUNTING BRACKET INSTALLATION” on this
page.
2.
CAUTION:
Verify that the module assembly fits
correctly into the lower mounting bracket. If the
space between the mounting brackets is incorrect,
relocate the brackets before proceeding with the
installation.
Place the module assembly into the lower
mounting bracket.
3. Place the upper mounting bracket in position
and attach it to the lower bracket with the mounting
bracket screws.
4. Connect the source water line to the System Inlet
Port. Connect the product water line to the
Outlet Port.
5. Open source water shut-off valve. Let the module
run for five minutes and check for leaks. Correct
leaks as necessary.
REVERSE OSMOSIS MODULE
NOTE:
Use thread sealing tape (P/N 35700002) on
male threaded connections.
1. Install lower brackets as instructed in Section
“MOUNTING BRACKET INSTALLATION” on this
page.
2.
CAUTION:
Verify that the module assembly fits
correctly into the lower mounting bracket. If the
space between the mounting brackets is
incorrect, relocate them before proceeding with
the installation.
Place the module assembly into the lower
mounting bracket.
3. Place the upper mounting bracket in position
and attach it to the lower bracket with the mounting
bracket screws.
4. Remove the Sump (Item 19) containing the
membrane (Item 23).