MECHANICAL FILTRATION OR REVERSE OSMOSIS MODULE
CLEANING, SANITIZING AND FILTER REPLACEMENT PROCEDURE
8
13. Slowly open source water supply valve.
14. Open outlet valve. Close valve as soon as water
begins to flow from port.
15. Wait 5 minutes, then close source water supply
valve.
16. Wait 25 minutes, then open outlet valve and let
water flow to drain.
17.
CAUTION:
Do not attempt to remove the sumps
until water flow stops. This releases the water
pressure within the system so sumps may safely be
removed.
Remove sumps and dispose of water. Rinse sumps
and manifold ports thoroughly with clean potable
water.
18.
CAUTION:
Do not remove protective plastic bag
from replacement filter/membrane cartridges until so
instructed.
Install "O" rings into sumps. Open top of filter bag
enough to expose filter cap and "O" ring grooves.
Place a small amount of "O" ring lubricant on surface
of each "O" ring.
19.
CAUTION:
Tighten sumps by hand only.
Do not use tools as they will over-tighten and
damage sumps. Take care not to cut or pinch
“O”
rings.
Install filter and membrane cartridges. Hold
cartridge by its protective plastic bag and insert
cartridge into manifold. Slide bag from cartridge and
discard. Replace sump as each cartridge is
installed.
20. Turn feed water valve slowly to open position.
21. Confirm system is producing water. Unit will be
sending rinse water to drain.
22. Open outlet valve. Let water flow until all air has
been expelled from the system.
23. Close outlet valve. Wait 5 minutes check
connections for leaks, and correct as necessary.
24. Allow system to operate for at least 30 minutes.
25. Sanitize the Product Water Storage Tank:
Atmospheric Tank: See instructions on Page 9.
Hydropneumatic Tank: Use Tank Sanitizing Kit
(P/N 42903007).
26. System is ready to use. Should there be any
aftertaste or odor, drain storage tank and repeat
Steps 24 and 25.