AquaTelemetry Instruction Manual
10401-01193 Rev H
2.19. Email Address Book Setup
In this field, input up to fifteen email accounts to which you wish logged data to be sent.
There is an index number on the left of the entry field along with an up/down arrow control
to allow you to scroll through all ten addresses. If you do not want to send logged data by
email, leave all ten email addresses blank.
When you have entered all the required email addresses, click the 'Update email Address
Book' button and ensure the data is echoed on the right of the screen.
2.20. SMS Phone Book Setup
SMS is the primary communication medium of the AquaTelemetry unit. It is used to
configure the system and to retrieve instantaneous level and alerts data. All SMS numbers
registered in the unit will also receive rate and level alerts as they occur in real time.
The AquaTelemetry unit allows the input of two classes of SMS phone number;
Administrator and User.
Any SMS numbers designated as Administrators can make changes to the AquaTel's setup
parameters and phone book by SMS.
Any SMS numbers designated as Users, can only access information and setup
parameters from the AquaTelemetry unit, they can not make any changes.
All SMS numbers registered will receive level and rate alerts.
Any SMS number, whether registered or not, can request level and alert data at any time.
Don't worry if you do not have all the required SMS numbers to hand at the time of initial
setup. SMS numbers can be added, altered and deleted later on by SMS by any registered
Administrator.
Be very careful when deciding which numbers to configure as administrators.
Administrators have the power to change all settings by SMS, including adding and
removing other SMS numbers from the SMS Phone Book.
It is essential to input at least one Administrator SMS number in order to allow
configuration of the unit. Without at least one Administrator, you will be unable to set
the unit up by SMS.
2.20.1. Phone Book Format
SMS numbers MUST be entered in the international format including the country code but
excluding the l and any spaces.
Each SMS number must also be preceded by either an 'A' or a 'U' to indicate whether that
number belongs to an Administrator or a User.
For example, to enter the UK mobile number
07881 523 164
as an
Administrator
, you
must enter:
A447881523164
© 2020 Aquaread
®
Ltd.
www.aquaread.com
Page 13 of 34