Unscrew the single fixing on top of the
processor box and carefully tilt the lid up
and off the location lugs and pull the lid
clear.
14
Connect the processor power lead to a
double pole 3 amp fuse switched spur
incorporated in the fixed wiring circuit,
in accordance with current wiring rules.
Ensure that this is located in an
accessible, dry location and not in the
bathroom.
13
THIS APPLIANCE MUST BE EARTHED
We recommend protecting surface mounted cables in suitable
approved conduit to avoid the risk of damage from vermin.
The data cable and power lead should also be clipped in place with
‘P’ clips or similar to avoid accidents.
!
BEFORE ANY ELECTRICAL ADJUSTMENT IS ATTEMPTED, THE
ELECTRICITY SUPPLY MUST BE TURNED OFF AT THE MAINS SWITCH.
ELECTRICAL INSTALLATION MAY ONLY BE CARRIED OUT BY A
QUALIFIED PERSON.
!
Connect the low voltage data cable into
the socket adjacent to the temperature
adjuster as indicated on the label.
Feed the cable out of the processor box
ensuring it is correctly routed within
the data cable channel.
15
A further data cable socket has been provided for use with a secondary
Rise Digital Wired remote start/stop controller. This can be accessed by
carefully snapping and removing the entry pillar and connecting the
cable as described above.
!