Symptom
Possible cause
Action
Water too hot.
Water flow too low.
a) Increase the flow by
turning the water control
knob towards the cold
temperature markings
(anticlockwise) slowly.
b) Ensure that the stop cock
and servicing valve are fully
open. If so, ask the installer
or the local water authority
to check that the running
pressure is above the
minimum requirement (see
Pressures section page
7). This may be apparent
during periods of high
demand or when other
outlets are used.
Spray plate and/or hose blocked
with scale or debris.
Clean the handset spray plate.
Remove hose and check for
restrictions. Run without the hose
attached to check temperature.
Incoming main water pressure or flow
too low.
After confirming that the filter is
clear, check with the installer or local
water authority.
Seasonal conditions - Warmer
inlet water temperature.
Set temperature dial to coolest
setting.
Note: Seasonal water conditions
influence the temperature range
of the shower. This applies to all
electric showers.
Temperature low Seasonal conditions
During winter months the
temperature of the incoming mains
water supply is low. Turn dial to
warmer setting and adjust spray
pattern on the shower head.