32
Symptom
Possible cause
Action
No flow or not
enough flow -
continued.
There may be an outlet
blockage.
Disconnect handset from hose and run
the shower.
i) If water flows, then handset is
blocked with scale or debris.
Clean the handset and spray
plate thoroughly.
ii) If the water does not flow,
remove the hose from the
shower outlet.
a) If the water flows, the hose
is blocked. This could be due
to damage, severe kinking or
even an obstruction. Replace
with a new hose.
b) If the water does not flow,
there is a blockage in the
plumbing to the shower, the
filter or the shower itself.
Contact our Customer
Service Department if the
shower is considered to be
the problem.
Blocked inlet filter.
Remove the filter for inspection.
PLEASE REFER TO CLEANING
AND MAINTENANCE SECTION.
Restricted operation of flow control
knob.
Remove front cover and check
operation of knob.
Flow adequate
but water too
cold.
Water flow is too high.
Reduce the flow by turning the
water control knob towards the hot
temperature markings (clockwise)
slowly.
Second stage thermal trip operated. This is a non serviceable part, shower
must be replaced.