22
UNI
MAX
Professional
CAUTION:
There is a glass element inside the housing (33), it should be particularly carefully handled during the cleaning of the
housing. Do not scrape, use a bottle brush only in order not to break the glass! In case of hard deposits a mild scale
removing agent can be used. After cleaning make sure to rinse the housing in clean water. In case of breaking the glass,
replace the entire housing (33).
After cleaning the container (10), install the flow cover (9) and sterilizer housing (33) in the container according to figures
5 and 6.
Fig. 27.
From the outside, from the bottom of the container (10) carefully insert the cleaned quartz casing (34) – along with
the gasket (24), fitting (36) and UV fluorescent lamp (35) into the UV sterilizer housing (33) in position shown on the figure,
then turn it clockwise according to arrow “IN”
until resistance
, into position shown on figure 26.
Check the tightness by pouring some water into the container (10). After the verification remove the water.
Check the UV sterilizer operation by connecting it for a moment to the power supply. [
We remind: the sterilizer operates
only in a condition of being completely installed in its housing (33)!
]
At that point, the routine maintenance of the UV sterilizer ends.
In case the sterilizer does not function – that means after connecting the sterilizer to the power supply the indicator lamp
on the plug ballast does not work – during the next filter maintenance the fluorescent lamp (35) should be replaced.
In order to do this the fitting (36) along with the fluorescent lamp (35) should be taken out from the quartz casing, accord-
ing to the description at figures 4 or 7.
Fig. 28.
Remove the old fluorescent lamp from the fitting. Remove the gasket (37), clean it and its groove, place it back in
the groove, lubricate lightly with Vaseline.
CAUTION
: Do not allow the water to enter inside of the quartz casing (34). If its interior gets wet it must be carefully
wiped dry.
Press the new fluorescent lamp (35) into the fitting (36) until locked.
CAUTION:
Do not touch the fluorescent lamp, remove the potential finger marks with a dry cloth.
Place the fitting (36) together with the fluorescent lamp (35) in the quartz casing (34) and screw it in anticlockwise
until
resistance
into the position indicated on figures 4 and 7. The insertion of the quartz housing (34) – with the fitting (36) and
a new UV fluorescent lamp (35) – into the UV sterilizer housing (33) should be done according to figure 27.
If the UV sterilizer still does not function after replacing the fluorescent lamp, address the manufacturer’s service.
Summary of Contents for UNIMAX PROFESSIONAL FZKN 150
Page 3: ...b a UNIMAX Professional FZKN 150 PLUS FZKN 250 PLUS...
Page 4: ...b a b...
Page 5: ......
Page 6: ...b a UNIMAX Professional FZKN 150 FZKN 250...
Page 89: ...83 8 8 1 5 8 8 2 4 7 3 8 3 15 21 16 21 22 8 4 AQUAEL 7 2 7 3...
Page 101: ...95 8 UV c 8 1 5 8 8 2 4 7 3 8 3 15 21 16 21 22 8 4 AQUAEL 7 2 7 3...