Page - 14
Surge Suppression
The use of approved commercial surge protectors is strongly recommended.
Sizing the Electrical Service
Refer to equipment data plate for specific information required to size electrical service and over-current
protection of the heat pump. Sizing is based on data plate information, wire size, wiring devices, and over-
current protection per applicable local codes and standards.
Minimum and Maximum Operating Voltage
The heat pump must operate within specified voltages.
NOTICE
Failure to heed the following may result in damage to equipment.
l
Operating equipment under higher or lower voltage conditions may result in damage to your compressor, motors
or other electrical components. This damage will not be covered by the product warranty.
1. Measure site voltage. The site voltage
MUST
be measured under “FULL LOAD” conditions. Activate all
equipment using the same electrical panel as the heat pump.
2. If measured site voltage is outside listed ranges, immediately deactivate equipment until site conditions have
been corrected. If unsure of heat pump equipment rating, please
Equipment Rating
Minimum
Site Voltage
Maximum
Site Voltage
A Voltage
(208 to 230 Volts)
Single Phase 60 hertz
200 Volts
253 Volts
B Voltage
(208 to 230 Volts)
Three Phase 60 hertz
200 Volts
253 Volts
D Voltage
(380 to 420 Volts)
Three Phase 50 hertz
361 Volts
441 Volts
G Voltage
(460 Volts)
Three Phase 60 hertz
437 Volts
483 Volts
H Voltage
(200 to 240 Volts)
Single Phase 50 hertz
180 Volts
264 Volts
Additional Adjustments
Additional information on electrical adjustments have been provided in the appendix of this document
including:
1.3.b Incoming Power Access Holes
1
-
Ins
ta
ll
at
ion
Summary of Contents for SunPower SP05
Page 2: ......
Page 70: ...Page 66 Water Source WS10 Water Source WS03 WS05 SunPower SP05 2 Appendix ...
Page 76: ...Page 72 l Follow all National Electric Codes NEC and or State and Local guidelines 2 Appendix ...
Page 77: ...Page 73 2 Appendix ...
Page 79: ...Page 75 2 10 Menu Trees 2 Appendix ...
Page 80: ...Page 76 2 Appendix ...
Page 107: ......
Page 108: ......