Page - 70
IF UNIT IS ASLEEP,
SWIPE TO WAKE UP
A
PRESS "MENU"
BUTTON
B
USE ARROWS TO
"GROUPS"
C
PRESS "ENTER"
1
USE ARROWS TO
GROUP TO EDIT
2
PRESS "ENTER"
TO EDIT
3
ARROWS TO "FREEZE
PROTECT ENABLED"
4
PRESS "ENTER"
TO EDIT
5
USE ARROWS TO
CHANGE TO "ON"
MENU TO EXIT, PRESS
& HOLD TO STATUS
Adjusting Freeze Protection Options
NOTICE
Failure to heed the following may result in damage to equipment.
l
Use extreme care when setting and adjusting freeze protection options. Improper freeze protection settings can
cause damage to equipment. This is not covered by heat pump warranty.
Available freeze protection options:
l
"PROTECT ON SETPOINT" can be adjusted from 33° F to 39° F (.6° C to 4° C). The
default is 37° F (3° C).
l
"PROTECT OFF SETPOINT" can be adjusted from 40° F to 45° F (4° C to 7° C). The
default is 42° F (5.5° C).
l
"CYCLE TIME" can be adjusted from 5 to 20 minutes. The default is 5 minutes.
l
"ACTIVE TIME" can be adjusted from 15 to 120 minutes. The default is 60 minutes.