![Aquacal SunPower SP05 Installation Manual Download Page 29](http://html1.mh-extra.com/html/aquacal/sunpower-sp05/sunpower-sp05_installation-manual_2959582029.webp)
Page - 25
C
PRESS "ENTER"
D
USE ARROWS TO
"ADVANCED"
E
PRESS "ENTER"
1
USE ARROWS TO MENU
"EXTERNAL CONTROL"
2
ENTER TO EDIT
3
USE ARROWS TO MODE
4
ENTER TO EDIT
5
USE ARROWS TO
"3WIRE POOL-OFF-SPA"
6
ENTER TO SAVE
MENU TO EXIT, PRESS
& HOLD TO STATUS
1.5 Connecting Multiple Heat Pumps (Optional)
Up to 16 heat pumps can be connected and controlled from a primary heat pump.
There are two reasons for using a multiple heat pump configuration:
1. Controlling multiple heat pumps from one location; the primary heat pump.
2. Preventing heat pumps from starting up at the same time and causing an excessive power
draw on the electric circuit.
NOTICE
Failure to heed the following may result in damage to equipment.
l
The wire size connecting the heat pumps must be 22-gauge, 2-conductor,
low-voltage wire. Be sure that the size of the wire will allow at least two
wires per connection point.
l
Do not attempt to connect heat pump equipment in multiple configurations
with previous HP7 and HP7R versions of the control board. See Figure 7.
No onboard port is provided for heat pumps with these control board
versions. An Automatic Sequencing Controller (ASC) accessory is
required for those types of heat pumps.
DO NOT
CONNECT
HP7 or HP7R
boards
Figure 7
1
-
Ins
ta
lla
tion
Summary of Contents for SunPower SP05
Page 2: ......
Page 70: ...Page 66 Water Source WS10 Water Source WS03 WS05 SunPower SP05 2 Appendix ...
Page 76: ...Page 72 l Follow all National Electric Codes NEC and or State and Local guidelines 2 Appendix ...
Page 77: ...Page 73 2 Appendix ...
Page 79: ...Page 75 2 10 Menu Trees 2 Appendix ...
Page 80: ...Page 76 2 Appendix ...
Page 107: ......
Page 108: ......