4.4 Heating Recommendations
The following recommendations will reduce the amount of time required to heat a pool.
If unsure of
equipment heating capability, review equipment data plate.
Identifying Model Specifications
1. Confirm heat pump mode has been set to heating mode.
2. Set the desired temperature (set-point) for the water.
3. Temporarily set the filter pump for continuous operation.
l
This will allow the Heat Pump the time required to heat the water at start-up.
l
After the water has reached the desired temperature, reset the filter pump to normal operating time-frames.
4. Activate Turbo Boost Mode if equipped.
5. Use a pool cover or blanket to reduce heating time.
4.5 Cooling Recommendations
The following recommendations will reduce the amount of time required to cool a pool or cold plunge
application.
If unsure of equipment cooling capability, review equipment data plate.
1. Confirm heat pump mode has been set to cooling mode.
2. Set thermostat to desired water temperature.
3. Activate Turbo Boost Mode if equipped.
4. Temporarily set the filter pump for continuous operation.
l
This will allow the Heat Pump the time required to cool the water at start-up.
l
After the water has reached the desired temperature, reset the filter pump to normal operating time-frames.
4.6 Available Accessories
Accessories may be purchased through an authorized dealer of AquaCal
®
products.
Bypass Valve Kit (# STK0135)
l
When high flow rates are outside recommended
specifications, please use this kit or an alternative bypass
valve system.
l
This kit can be used to control excessive water flow
through the heat pump. It provides automatic flow
adjustments for most applications.
Condensation Drain Kit (# STK0202)
l
Used when condensation water flow must be directed to a
specific location.
4
-
A
ppe
ndi
x
Summary of Contents for HeatWave SuperQuiet SQ120R
Page 2: ......
Page 11: ...Page 8 1 Operation ...
Page 13: ...Page 10 1 Operation ...
Page 17: ...Page 14 Set Efficiency Mode to 24 Hour 1 Operation ...
Page 18: ...Page 15 Set Efficiency Mode to Filtration Schedule 1 Operation ...
Page 19: ...Page 16 1 Operation ...
Page 21: ...Page 18 Configure for Call mode 1 Operation ...
Page 22: ...Page 19 Configure for Flex mode 1 Operation ...
Page 53: ...Page 50 Model Number Example 4 Appendix ...
Page 58: ......