Page - 20
1.7.b Operating Heat Pump (With an External Controller)
If the display indicates the unit is under remote
control, an external control device has been
configured to control the heat pump. See the
external control device manual. Or contact
installer or manufacturer of that device.
PLEASE NOTE:
When using a SMART external control device, the time-out and service modes will
deactivate the Heat Pump.
1.7.c Operating Heat Pump (With an External Flow Switch)
When an external flow switch has been installed and enabled, the heat pump will automatically switch from
pool to spa temperature settings when there is flow through the external flow switch. The "Pool/Spa" button
will be disabled when this device is configured in the system.
Confirm with the installer if an external flow switch has been installed on the system.
1.7.d Operating Heat Pump (With a Gas Back-Up)
If a gas backup heater is installed, it will be configured in one of two modes by the installer (Scheduled mode
or 24-hour mode). This affects how the heater operates.
PLEASE NOTE -
Gas backup
modes
are only available when the ambient air temperature is below 60° F.
" on the next page for an exception.
Scheduled Mode
When heating the Pool
:
l
The heat pump will operate for one hour. Then a calculation is made on how fast the water temperature is
rising (a rate of rise).
l
If an insufficient amount of time is provided for the heat pump to heat the water, the gas backup heater will
be activated.
l
When the set temperature has been reached, the gas heater will deactivate.
l
The heat pump will continue to maintain the water temperature.
When heating the Spa
:
l
If the water temperature is lower than 2° F (-16.7° C) below the set temperature, and the ambient air
temperature is below 60° F (15.6° C), the gas heater will activate.
l
When the set temperature has been reached, the gas heater will deactivate.
l
The heat pump will continue to maintain the water temperature.
1
-
O
pe
ra
tion
Summary of Contents for HeatWave SuperQuiet SQ120R
Page 2: ......
Page 11: ...Page 8 1 Operation ...
Page 13: ...Page 10 1 Operation ...
Page 17: ...Page 14 Set Efficiency Mode to 24 Hour 1 Operation ...
Page 18: ...Page 15 Set Efficiency Mode to Filtration Schedule 1 Operation ...
Page 19: ...Page 16 1 Operation ...
Page 21: ...Page 18 Configure for Call mode 1 Operation ...
Page 22: ...Page 19 Configure for Flex mode 1 Operation ...
Page 53: ...Page 50 Model Number Example 4 Appendix ...
Page 58: ......