Page - 46
Ice Forming on the Heat Pump
Ice Forming on the Heat Pump
ISSUE
When conditions are too cold for proper operation, the heat pump will enter a defrost mode. This
prevents ice from building up on the evaporator coil.
RESOLUTION
Heat Only Units:
l
The heat pump may develop a fine layer of white frost on the outside coil before entering the defrost
mode. This is normal.
l
l
If heavy ice (not frost) starts to build up, shut off the heat pump. Contact the installer or manufacturer.
l
If the ambient air temperature will be falling below 32° F (0° C) for more than 8 hours, winterize
equipment.
l
Cool Only Units
l
The heat pump may enter defrost mode if the water flow rate falls below the acceptable range.
l
If the ambient air temperature will be falling below 32° F (0° C) for more than 8 hours, winterize
equipment.
l
Heat and Cool Units (with Active Defrost or “Icebreaker”):
l
During freezing conditions, pool or spa heating will continue. Frost or ice may develop during the
“countdown” to the active defrost (up to 50 minutes). This is normal.
l
The heat pump will enter an "active defrost" stage to remove the accumulated frost and ice.
l
Be sure to observe the unit for at least 50 minutes. If it has not entered an active defrost cycle, call
for service.
TIP:
The heat pump can be manually set to defrost by temporarily switching to the
cooling mode until the ice or frost melts.
l
If the ambient air temperature is (or will be) falling below 32° F (0° C) for more than 8 hours,
winterize equipment.
l
"Pool / Spa" Button Will Not Work
ISSUE
The "Pool / Spa" button is disabled if the following devices have been configured on the heat pump.
Check with installer if unsure of devices enabled on heat pump.
RESOLUTION
l
A 2-wire external controller.
l
A 3-wire external controller.
l
An external flow switch.
3
-
T
roubl
es
hoot
ing
Summary of Contents for HeatWave SuperQuiet SQ120R
Page 2: ......
Page 11: ...Page 8 1 Operation ...
Page 13: ...Page 10 1 Operation ...
Page 17: ...Page 14 Set Efficiency Mode to 24 Hour 1 Operation ...
Page 18: ...Page 15 Set Efficiency Mode to Filtration Schedule 1 Operation ...
Page 19: ...Page 16 1 Operation ...
Page 21: ...Page 18 Configure for Call mode 1 Operation ...
Page 22: ...Page 19 Configure for Flex mode 1 Operation ...
Page 53: ...Page 50 Model Number Example 4 Appendix ...
Page 58: ......