SAFETY INFORMATION
(CONTINUED)
READ AND FOLLOW ALL INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
All DIG-220 models:
Installation of fixed wiring DIG-220 (115/230Vac, 50/60 Hz):
A disconnect device such as a time clock relay or circuit breaker from the pow
er
source, with a contact separation of at least 0.12” (3mm) in all poles, must be
incorporated in the fixed wiring for permanently wired units.
To avoid personal injury
WARNING
Risk of Electrical Shock.
WARNING
Ensure that the electrical panel or filter pump circuit is turned OFF prior to
in
stallation or servicing inside any Auto
P
ilot unit.
Mount the Control Box to ensure the least amount of direct exposure to rain,
garden sprinkler water, direct sunlight, or any corrosive environment.
Risk of Electrical Shock.
WARNING
Install the Control Box at least 10’
(3 m) for 115 Vac Units, from the inside
wall
of the pool or s
pa.
Use 5’ (1.5 m) minimum distance for 230 Vac Units.
Risk of Electrical Shock.
WARNING
Do not permit children to use this product unless they are closely supervised
at
all times. Children should not use spas, hot tubs, or pools
without
permanent
adult supervision.
Failure to heed the following may result in permanent injury or death.
WARNING
All field-installed metal components such as rails, ladders, drains, or simila
r
hardware within 10’(3 m) of the spa or hot tub shall be bonded to the equip
ment
grounding bus with copper conductors not smaller than No.8 AWG (8.4 mm²).
To avoid personal injury
WARNING
Use the bonding lug provided on the outside of your DIG-220, to connect a min-
imum No. 8 AWG (8.4 mm²) solid copper bonding conductor between the DIG-
220 and any metal equipment, metal enclosures of electrical equipment, metal
water pipe or conduit within 5’ (1.5 m) of the DIG-220.
To avoid personal injury
WARNING
A ground terminal is located on the inside of your DIG-220
. To
reduce the risk
of
electrical shock, this terminal must be connected to the grounding means
provided in the electrical supply panel. A continuous copper wire is to be
used
equivalently sized to the circuit conductors supplying your DIG-220.
To avoid personal injury
WARNING
The input voltage to the DIG-220 must match the
1
1
5/230Vac jumper
terminals
on the Circuit board, marked “TRANSFORMER PRIMARY” (shown
on Page-1
4
& 15).
To avoid personal injury
WARNING
The proper residual chlorine level and water chemistry must be maintained.
To avoid personal injury
WARNING
The Control Box is provided with (3) knock out holes for electrical conduit con-
nections and has (1) 1/2” Liquidtite fitting already attached. 1/2” nonmetallic flex
conduit is recommended.
To avoid personal injury
WARNING