23
PROGRAMMING
(CONTINUED)
Cell Power:
1.
Press or
until “
Set cell power
” is displayed; then press SELECT (Power level 1 is the factory setting).
2.
Press or
until the desired power level (1,2, or 3) is displayed; the press SELECT
.
(See recommendations on pg 31 for when to change cell power. Factory setting is cell power
1
)
Cell Type:
1.
Press
or
until “
Set Cell Type
” is displayed; then press SELECT (
PPC3
is the factory setting).
2.
Press or
until the desired cell type (
PPC1
,
PPC3
,
PPC4
, or
PPC
5) is displayed, then press SELEC
T
.
(Must match the installed cell)
Pump Control:
1.
Press or
2.
Press or
until “
Set Pump Control
” is displayed; then press SELECT (external timer is the factory setting).
until the desired pump configuration (One-speed pump, two-speed pump, remote runs pump or external timer) is displayed; then press SELECT.
(Program DIG-220 to accept a one-speed pump, two-speed pump, remote, or external timer) Note - optional pump relay must be installed.
Set Time of Day:
1.
Press or
until desired hours are displayed; then press SELECT.
2.
Press or
until the desired minutes are displayed; then press SELECT.
(Allows for changes to the time of day displays for time zones or day-light savings.)
Select Remote:
1.
Press or
until “
Select remote
” is displayed, then press SELECT (Remote 1).
2.
Press or
until the desired remote (1 or 2) is displayed, then press SELECT
.
(Selects type of external controller. Need Pump control programmed for “remote runs pump” in
order to use this option.)
Pump Program 1 and 2:
1.
Press or
until “
Pump program X
” is displayed; then press SELECT.
2.
Press
to program the pump, press D to Delete the program or SELECT to exit with no change.
- If is selected, use or
to select hours, then SELECT. Repeat for minutes.
Note: The pump programs are only accessible if a one or two speed pump is selected in the pump configuration
.
There are two programs available for high speed
operation.
Low speed operation is not programmable and pump will run continuously on low speed unless pump program is calling for high speed.
A separate switch is recommended to turn off low speed pump operation when servicing system
.
Exit Menu Mode
Press SELECT to exit menu entry.
END OF PROGRAMMING SECTION
Enable Demo:
(This is a special display mode, which does not impact salt readings or temperature readings. Note that chlorine will not be
re
gen
e
rated even though valid readings for
volts
and
a
mps will show on the “Test Pool Pilot” menu.)
1.
Press MENU; press or
until
“Installer Menu”
is displayed; then press SELECT.
2.
To disable demo mode, press or
until “Disable demo” is displayed, then press SELECT. Unit will reset and operate in normal mode.
3.
To enable demo mode, press or
until “Enable demo” is displayed, then press SELECT.
*** DEMO *** will flash, then DIG-220 will reset into demo mode.
Select Minerals:
1.
Press
or
until “Select minerals” is displayed, then press SELECT (Salt).
2.
Press or
until the desired display mode (Salt or Minerals) is displayed; then press SELECT
.
(This is a special display mode, which does not impact salt readings or other functionality)