5
Used and maintained properly, your chlorine generator will provide year-upon-year of safe and economical
service. However, as with any mechanical or electrical device, to get the most from your equipment—
while insuring personal safety for you and others—certain operational and maintenance factors must
be observed.
Likewise, excepting a few minor owner-capable maintenance items (explained later in this manual), repair
and service of your chlorinator must be performed only by experienced service personnel. Should you,
the owner, suspect your chlorine generator is not performing properly, please refer to the section in this
manual entitled: "Troubleshooting." You can also access the most current troubleshooting advice at
www.autopilot.com. If you determine that a service call is necessary, your installer can be one source
of service, or AquaCal AutoPilot Customer Support can recommend a service company.
Please note that warranties may be voided if the chlorinator has been installed, operated, maintained,
or repaired improperly. In addition to voiding the manufacturer’s warranty, unapproved installation methods,
modifications, poor or incorrect maintenance, service by unqualified personnel, or improper use of the
chlorinator may result in personal injury and/or property damage. For personal safety, and to avoid damage
to equipment, follow all safety instructions displayed on the equipment and within this manual.
SAFETY INFORMATION
Throughout this manual the following two safety signals are placed where particular attention is required.
Please note "WARNING" relates to personal safety, while "CAUTION" signals promote avoiding damage
to equipment.
Safety Signals
Safety Information Main Table
A “warning” signal appears in this manual where special attention is required for personal safe-
ty. (Specific instructions will appear in this box.)
Failure to heed the following may result in permanent
injury or death.
WARNING !
A “caution” signal appears in this manual where special care is required to avoid equipment dam-
age. (Specific instructions will appear in this box.)
Failure to heed the following may result in equipment
damage.
CAUTION !
Failure to heed the following may result in permanent
injury or death.
WARNING !
RISK OF ELECTRICAL SHOCK - A bonding lug has been provided on the outside of the Control
Unit. This lug permits the connection of a No. 8 AWG (8.4mm
2
) solid copper-bonding conductor
(No. 6 AWG in Canada). Make this connection between the Control Unit and all other electrical
equipment and exposed metal within 5-feet (1.5m) of the Control Unit. All field-installed metal
components (such as rails, ladders, drains, etc.) within 10-feet of the pool, spa, or hot tub, must
be bonded to the equipment grounding bus using copper conductors not smaller than No. 8-AWG
(8.4mm
2
) (No. 6 AWG in Canada).
CHLORINATOR CONTAINS NO OWNER-REPAIRABLE COMPONENTS - Repairs must not be
attempted by untrained and/or unqualified individuals. If service is deemed necessary, contact in-
stalling dealer or AquaCal AutoPilot Customer Support at: (727) 823-5642.
Failure to heed the following may result in permanent
injury or death.
WARNING !
Follow all National Electric Codes (NEC) unless State or Local guidelines supersede. When installing
and using your AG, basic safety precautions must always be followed, including the following:
Summary of Contents for 75090
Page 30: ...30...
Page 31: ...31...
Page 32: ...32 2737 24th St North St Petersburg FL 33713 1 727 823 5642...