23
The flow switch is a critical component to the 75094 Inline Manifold system . When water flow has stopped,
to prevent damage to the cell or system, it is important power to the SuperCell be automatically turned
OFF. The water flow switch performs this function.
In order to test that this component is working properly:
1. Turn off circulation pump.
2. Confirm that the AG system is still receiving power. (Some AG systems will be installed to turn
off when the water pump is off). Please follow all safety codes when routing power to the unit.
DO NOT use an extension cord to provide power to the unit.
3. Verify that the red “Check System” light is flashing. The AG system will also display “no Flo” in
a scrolling message. This means it has no water flow. If the check system light does not turn on,
please verify that the flow switch jumper is NOT installed, then have the unit serviced.
4. Turn on the water pump. The red “Check System” light should turn off showing the unit has water
flow.
5. Turn off water pump and route power back to normal.
Testing the Flow Switch
(for Inline Manifold system)
Fuse Location and Ratings:
To inspect or service fuse:
•
Disconnect power to power supply.
•
Take a straight screw driver as indicated and turn counter clockwise to loosen fuse holder on bottom
of unit.
•
Gently pull out fuse holder. Replace fuse as shown on chart below and reconnect fuse holder.
ELECTRICAL SHOCK HAZARD... Turn off the electrical power to unit before servicing.
Failure to heed the following may result in permanent
injury or death.
WARNING !
MAINTENANCE
Board
Fuse Specification
Description
Main Power Board 75090
250 Vac 2 Amp Slow Blow Main AC Power Fuse
Main Power Board 75090-TL
250 Vac 2 Amp Slow Blow Main AC Power Fuse
Main Power Board 75091
250 Vac 1 Amp Slow Blow Main AC Power Fuse