AQUA SALT EVO
MAINTENANCE AND INSTRUCTION MANUAL
Salt chlorine generator
ENGLISH
ADSP7000753
rev. 2.0
23/04/2019
87/96
87
Flow & Pressure filter
Indicates or sets the duration of flow
& pressure filter, i.e. the minimum
time must be present to be recorded.
Display
Work mode
Indicates or sets the pH
work mode (Acid, Alkaline).
Cell type
Indicates or sets the cell type (50,
100, 150, 200).
LCD contrast
Indicates or sets the LCD contrast value.
Proportional Range
Indicates or sets the value
of the pH proportional
range.
Type of minerals
Indicates or sets the type of minerals
(Salt, Minerals).
LCD mode
Indicates or sets the work mode of the LCD display
(60 seconds ON, Always ON).
Cycle period (minutes)
Indicates the cycle period
of the pH correction, i.e.
the sum of the ON and
OFF time of the pump.
Polarisation time
Indicates or sets the polarisation time
of the cell, i.e. the time for which the
polarity of the voltage sent to the cell
stays positive or negative.
Clock type
Indicates or sets the clock type (12 or 24 hours)
Salinity
Temperature unit
Indicates or sets the unit of measurement of
temperature (Celsius, Fahrenheit).
Set point
Indicates or sets the Set Point value
of salinity.
System unit
Indicates or sets the unit of measurement of pool
capacity (cu. m, imperial gallons)
Proportional Range
Indicates or sets the value of salinity
proportional range.
Salinity unit
Indicates or sets the unit of measurement of salinity
(g/l, ppm).
Cycle period (minutes)
Indicates or sets the cycle period of
salinity correction, i.e. the sum of the
ON and OFF time of the pump.
✓
The
TIMER
tab programmes two kinds of timers: recirculation timers manage ignition and shut-down of
the recirculation pump; internal timers programme the ignition and shut-down of the chlorine generator, if
set on Internal timers mode.
Recirculation timer
Timer
Enabling
Indicates or sets the global enabling state of the 12
recirculation timers (On, Off).
1..4
Identification
number
of
the
Internal
timer.
Type
Indicates or
sets the type
of
internal
timer (Off,
Mon-Fri,
Mon-Sun,
Sat-Sun).
Start
Indicates or
sets the time
of activation
of
the
internal
timer.
Duration
Indicates or
sets
the
duration
of
the
internal
timer.
1..12
Identification
number
of
the
Recirculation
timer.
Type
Indicates or
sets the type
of
Recirculation
timer (Off,
Mon-Fri,
Mon-Sun,
Sat-Sun).
Start
Indicates or
sets
the
time
of
activation of
the
recirculation
timer.
Duration
Indicates or
sets
the
duration of
the
recirculation
timer.
✓
Through the
ALARMS
you can enable, disable and set the alarms you prefer.
Alarms enabling
Electrolytic Cell Maintenance
Audible alarm enabling
Indicates or sets the enabling state of the audible
alarm (On, Off).
Cell Maintenance (hours)
Indicates or sets the duration of the Cell maintenance interval.
Recirculation pump state alarm enabling
Indicates or sets the enabling state of the
"Recirculation pump state" alarm (On, Off).
Cell Replacement (hours)
Indicates or sets the duration of the life cycle of the cell.
Low production alarm enabling
Indicates or sets the enabling of the "Low production"
alarm (On, Off).
Current alarm enabling
Indicates or sets the enabling of the "(low) voltage" alarm (On,
Off).
Insufficient production alarm enabling
Indicates or sets the enabling of the "Insufficient
production" alarm (On, Off).
Temperature probe alarm enabling
Indicates or sets the enabling of the "Temperature probe" alarm
(On, Off).